Datasheet

Specifications of MN114

Test Probe Type
Multimeter
Test Probe Functions
Current
Accuracy
± 3.5%
For Use With
DMMs
Lead Free Status / RoHS Status
na
Specifications
Note: Reference conditions:
MODELS
ELECTRICAL
Nominal Range
Measurement Range
Transformation Ratio
Output Signal
Accuracy (10A Range)
Phase Shift (10A Range)
Overload
Frequency Range
Load Impedance
Working/Common
Mode Voltage
Output Termination
MECHANICAL
Operating Temperature
Storage Temperature
Operating Relative
Humidity
Jaw Opening
Maximum Conductor Size
Dimensions
Weight
Polycarbonate Material
SAFETY
Electrical
23°C ±3K, 20 to 70%RH, 48 to 65Hz, external magnetic field < 40A/m, no DC component, no external current carrying conductor,
test sample centered, load impedance 1MΩ.
1mA to 10A
1mA to 10A
Technical Assistance (800) 343-1391
250V working voltage, 250V max common mode between
output and ground, 3kV 50/60Hz dielectric for 1mm
Handles 10% fiberglass charged polycarbonate UL94 VO
10 to 35°C 85% RH (without roll-off above 35°C)
1.26 x 4.53 x 0.87" (32 x 115 x 22mm)
40Hz to 3kHz: 3.5% of Reading ± 2mA
1mA to 10A: 2% of Reading ± 2mA
45 to 65Hz 100mA to 10A: ≤8°
-40° to 176°F (-40° to 80°C)
14° to 122°F (-10° to 50°C)
0.47"Ø max (12mm)
20A continuous
Voltage output
0.78" (20mm)
5.6 oz (160g)
100mV
30Hz to 5kHz
1mA to 10A
(1V @ 10A)
100Ω min
MN114
5 ft Lead
250V
10A
AC
AC
/A
AC
AC Current Probe Model MN114 (pdf) Rev. 03 10/05
www.aemc.com
2 of 4