FLUKE-975VP Fluke, FLUKE-975VP Datasheet - Page 3

AirMeter Air Velocity Probe

FLUKE-975VP

Manufacturer Part Number
FLUKE-975VP
Description
AirMeter Air Velocity Probe
Manufacturer
Fluke
Datasheets

Specifications of FLUKE-975VP

Features
Ideal For One-Touch Air Flow And Velocity Measurements
Measures
Air Velocity, Humidity, and Temperature
For Use With
Fluke 975 AirMeter Air Quality Analyzer
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Fluke 975 AirMeter specifications
Ordering Information
Fluke-975
Fluke-975V AirMeter
Included
AA alkaline batteries (3)
Users manual (with safety information)
Calibration cap
Hard carrying case
FlukeView
Power adapter
International power plugs
Air velocity probe (Fluke 975V only)
Optional accessories
ToolPak
Fluke-975CK AirMeter Calibration Kit
Fluke-975VP AirMeter Air Velocity Probe
Feature
Measured specifications
Temperature
Relative humidity
Air velocity
CO
CO
Calculated specifications
Dew point temperature
Wet bulb temperature
Volume flow rate (in a duct)
% outside air
(based on temperature)
% outside air (based on CO
General specifications
Operating temperature:
CO and CO
Operating temperature:
All other functions
Storage temperature
Humidity
Altitude
Shock and vibration
Multi-language interface
Battery
Data logging
Warranty
2
Magnetic Meter Hanging Kit
®
2
sensors
Forms software
AirMeter
2
)
with Velocity
Range
-20 °C to 50 °C
(-5 °F to 122 °F)
10 % to 90 % RH
non-condensing
0.50 fpm to 3000 fpm
0.25 m/sec to
15 m/sec
0 to 5000 ppm
0 to 500 ppm
-44 °C to 50 °C
(-47 °F to 122 °F)
-16 °C to 50 °C
(3 °F to 122 °F)
0 to 3,965 M
(0 to 140,000 cfm)
0 to 100 %
0 to 100 %
-20 °C to 50 °C (-4 °F to 122 °F)
-20 °C to 50 °C (-4 °F to 122 °F)
-20 °C to 50 °C (-4 °F to 122 °F)
10 % to 90 % (non-condensing)
Up to 2000 m (6562 ft)
MIL-PRF-28800F: Class 2
English, French, Spanish, Portuguese and German
Rechargeable Li-Ion (primary), three-AA (backup)
25,000 records (continuous), 99 records (discrete)
Two-years
3
/m
Fluke 975V pictured
Display resolution
0.1 °F
(0.1 °C)
1 %
1 fpm
(0.005m/sec)
1 ppm
1 ppm
0.1 °C
(0.1 °F)
0.1 °C
(0.1 °F)
0.001 M
(1 cfm)
0.1 %
0.1 %
3
/min
Accuracy
± 0.9 °C/± 1.62°F from 40 °C to 50 °C
± 0.5 °C/± 1.00°F from 5 °C to 40 °C
± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
± 2 % RH (10 % RH to 90 % RH)
± 4% or 4 fpm*
± 4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm.
Warm up time 1 min (5 minutes for full specification)
2.75 % + 75 ppm
± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and
50 % RH
± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 50 °C
± 2.1 °C when RH: 10 % to 20 %
N/A: The volume flow calculation will be a simple average
of the data points times the duct area
N/A
N/A