GLD450 KANE KAY, GLD450 Datasheet - Page 2

PROBE, GAS LEAK DETECTOR

GLD450

Manufacturer Part Number
GLD450
Description
PROBE, GAS LEAK DETECTOR
Manufacturer
KANE KAY
Datasheet

Specifications of GLD450

Svhc
No SVHC (15-Dec-2010)
Lead Free Status / RoHS Status
na
The most user friendly “5 in 1” analyser available
Combustion Analyser
CO Meter
Calibrate the analyser in fresh air to set the CO
sensor to zero
Gas Leak Detector
Select “Ratio” on the rotary switch to view
current fuel, CO/CO
Select “O
efficiency
Select “Aux” to view any 4 parameters, user
selectable
Measures O
Calculates CO
and combustion efficiency, (nett, gross or
condensing)
Multi fuel - Natural gas, Propane, Butane, LPG
and Light Oils (28/35sec)
Readings can be printed via an infra-red printer,
(see printout example)
Memory stores up to 99 combustion tests
Select “Ratio” to check the ambient CO level in
a room
Select “Room CO” to perform a 15 minute CO
test
The CO level is logged at 1 minute intervals
“Room CO” tests are automatically stored in the
memory
Tests can be printed via an infra-red printer,
(see printout example)
Memory stores up to 20 “Room CO” tests
Plug-in, handheld unit with the sensor at the tip
of a flexible shaft
LED’s and a variable buzzer enable the user to
pinpoint a gas leak
Can detect leaks down to 50ppm of methane /
natural gas
2
/Eff” to view O
2
, CO, inlet and flue temperatures
(#4)
2
, CO/CO
2
ratio, CO, and CO
2
ratio, excess air, losses
2
, temperatures and
(#5), optional
(#1)
2
“Made to Measure” for
6
CORGI
/
Registered Engineers
Differential Pressure Meter
Differential Thermometer
Torch Light
Select “Prs” on the rotary switch for high
accuracy single or differential pressure
readings
Range ± 80mBar, maximum resolution
0.001mBar
Ideal for difficult applications such as flue
draught
Readings can be smoothed to damp out
pressure pulsing
Ideal for setting air/gas ratio valves
Display includes a clock for manual timing,
let-by test
Readings can be printed via an infra-red
printer, (see printout example)
Memory stores up to 20 pressure tests
Select “Tightness” to perform a let-by test and
stabilisation/tightness test
The let-by period defaults to 1 minute
The stabilisation period defaults to 1 minute
The tightness test period defaults to 2 minutes
All 3 times can be adjusted by the user
Tests are automatically stored in the memory
Tests can be printed via an infra-red printer,
(see printout example)
Memory stores up to 20 “Tightness” tests
Select “Diff Temp” to view flow (T1), return
(T2) and differential (∆T) temperatures
Temperature probes are available to measure
air, liquid and surface (pipe) temperatures
Ideal for Benchmark log book
Readings can be printed via an infra-red
printer, (see printout example)
Memory stores up to 20 differential
temperature tests
Never got a torch when you need one? You
have now!
The KANE425 has a backlit display and an
inbuilt LED torch
(#6)
(#3)
(#2)