DS1841N+ Maxim Integrated Products, DS1841N+ Datasheet
DS1841N+
Specifications of DS1841N+
Related parts for DS1841N+
DS1841N+ Summary of contents
Page 1
... Address Pins Allow Up to Four DS1841s to Share the Same I ♦ Digital Supply of 2.7V to 5.5V 2 C-compatible ♦ -40°C to +100°C Operating Range ♦ 3mm x 3mm, 10-Pin TDFN Package Applications PART DS1841N+ DS1841N+T&R + Denotes a lead-free package. T&R = Tape and reel Exposed pad. TOP VIEW 3.3V V APD V OUT 0.1μ ...
Page 2
Temperature-Controlled, NV, I Logarithmic Resistor ABSOLUTE MAXIMUM RATINGS Voltage Range on SDA, SCL, and V Relative to GND .........................................-0.5V to +6.0V CC Voltage Range on RH, RW, A0, and A1 Relative to GND ................................-0. Operating Temperature Range .........................-40°C ...
Page 3
TEMPERATURE SENSOR CHARACTERISTICS (V = +2.7V to +5.5V -40°C to +100°C, unless otherwise noted PARAMETER SYMBOL Temperature Error Update Rate (Temperature and t FRAME Supply Conversion Time) ANALOG VOLTAGE MONITORING CHARACTERISTICS (V = +2.7V to +5.5V, ...
Page 4
Temperature-Controlled, NV, I Logarithmic Resistor ELECTRICAL CHARACTERISTICS (See Figure 3) (continued +2.7V to +5.5V -40°C to +100°C, timing referenced PARAMETER SYMBOL EEPROM Write Time A0, A1 Setup Time ...
Page 5
T = +25°C, unless otherwise noted SUPPLY CURRENT vs. SUPPLY VOLTAGE 250 200 LUT MODE AND LUT ADDER MODE LUT MODE AND LUT ADDER MODE UPDATE MODE BIT = 1 UPDATE MODE BIT ...
Page 6
Temperature-Controlled, NV, I Logarithmic Resistor PIN NAME 2 1 SDA I C Serial Data. Input/output for I 2 GND Ground 3 V Power Supply Address Select Inputs. Determines I Slave Address Byte and Address Pins sections for ...
Page 7
LUT Adder Mode (Default) LUT Adder Mode is selected by setting the Update Mode bit to 1 and the Adder Mode bit to 1. This mode operates similar to LUT Mode with one major difference (see the LUT Mode and ...
Page 8
Temperature-Controlled, NV, I Logarithmic Resistor LUT Mode and LUT Adder Mode Block Diagram (Update Mode Bit = GND CONTROL SCL LOGIC/ REGISTERS SDA INTERFACE A0 A1 DATA TEMP SENSOR ADC V CC VOLTAGE *NOTE ...
Page 9
DECREASING LUT34 TEMPERATURE LUT33 LUT32 INCREASING LUT31 TEMPERATURE LUT30 1°C HYSTERESIS WINDOW TEMPERATURE (°C) Figure 1. LUT Hysteresis MSB SLAVE ADDRESS* *THE SLAVE ADDRESS IS DETERMINED BY ADDRESS PINS A0, ...
Page 10
Temperature-Controlled, NV, I Logarithmic Resistor Memory Description The DS1841’s internal memory consists of both volatile and NV registers that are organized into eight byte Register 00h: Initial Value Register (IVR) FACTORY DEFAULT (IVR) 00h MEMORY TYPE NV MEMORY TYPE Volatile ...
Page 11
Register 03h: Control Register 1 (CR1) FACTORY DEFAULT 03h MEMORY TYPE Shadowed NV 03h Reserved Reserved Bit 7 Bits Reserved. Adder Mode This bit is valid only if the Update Mode bit = 1. Bit 1 0 ...
Page 12
Temperature-Controlled, NV, I Logarithmic Resistor Register 0Ah: Control Register 2 (CR2) FACTORY DEFAULT 00h MEMORY TYPE Volatile 0Ah Reserved Reserved Bit 7 Bits Reserved. Wiper Access Control This bit is valid only in LUT Mode and in ...
Page 13
Registers 80h to C7h: Temperature Lookup Register (LUT) FACTORY DEFAULT 00h MEMORY TYPE NV 80h to C7h Bit 7 These registers at location 80h to C7h are NV and serve to temperature compensate RW over the operating temperature range of ...
Page 14
Temperature-Controlled, NV, I Logarithmic Resistor SDA t BUF t LOW SCL t HD:STA STOP START NOTE: TIMING IS REFERENCE TO V AND V IL(MAX) IH(MIN) Figure Timing Diagram Byte read: A byte read is an 8-bit ...
Page 15
Writing multiple bytes to a slave multiple bytes can also be performed. During a sin- gle write sequence bytes in one page can be written at one time. If more than eight bytes are trans- ...
Page 16
Temperature-Controlled, NV, I Logarithmic Resistor tion, writes the slave address byte (R/W = 1), reads data with ACK or NACK as applicable, and generates a STOP condition. See Figure 4 for I Examples. Applications Information Power-Supply Decoupling To achieve the ...
Page 17
... DATE 0 11/07 Initial release. In Ordering Information table, changed part numbers from DS1841T+/DS1841T+T&R to DS1841N+/DS1841N+T&R. 1 3/08 In the Typical Operating Characteristics, corrected the supply current for TOCs 1, 2, and 3 from mA to μA. In Register 03h: Control Register 1 (CR1), changed the factory default from 00h to 03h ...