6145.0031.001 Schurter Inc, 6145.0031.001 Datasheet - Page 5

no-image

6145.0031.001

Manufacturer Part Number
6145.0031.001
Description
6.ABTWF150C0.001
Manufacturer
Schurter Inc
Series
6145r
Datasheets

Specifications of 6145.0031.001

Connector Style
IEC 320-C14
Connector Type
Receptacle, Male Pins - Module
Number Of Positions
3
Current
15A
Voltage
125V
Mounting Type
Panel Mount, Screw Hole
Termination Style
Quick Connect - .250" (6.3mm)
Fuse Drawer
Fuse Not Required
Features
Circuit Breaker, Non Illuminated, Switch On/Off
Alt Mfr.s Type
6145.ABTWF150C0.001
Current Rating
10 to 20 A (UL, CSA)
Dielectric Strength
> 1.5 kV (Between Line-Natural)
Dimensions
100 mm H x 36 mm W
Material, Housing
Thermoplastic
Number Of Poles
1
Standards
UL Recognized, CSA Certified, VDE Approved
Terminal Style
Quick-Connect
Voltage, Rating
125⁄250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power entry modules without line filter
The specifications, descriptions and illustrations indicated in this document are based on
Technical data (continued)
Circuit breaker
Tripping characteristics
I
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for a lower or higher ambient tempera-
ture, use a correction factor from the table below.
* Ambient temperature [°C] Correction factor
–10
– 5
+23
+30
+40
+55
Order code (Order example)
Please note that Schurter will establish an internal part number for logistical use in addition to the order code.
The format of this internal part number is, for example 6145.0031.001
n
Type
6145
[ min ]
60
30
20
10
< 3 A
5
1
0
10’000
2000
1000
[ sec ]
500
200
100
.
0,5
0,3
0,2
0,1
50
20
10
5
2
1
A B T W F 1 5 0 C 0
Multiple of rated current
1,05
Order code TA 45
(2-pole rocker-switch without
accessories)
current information. All content is subject to modifications and amendments.
1,32
Type
Rated current
Ambient temp.
2
see table 1
3
[ x I n ]
4
5
TA45
I n < 3 A
1-pole protected
2-pole protected
+23 °C
1)
8
0,89
0,91
0,92
1,00
1,03
1,08
1,16
10
.
0 0 1
60
10
[ min ]
30
20
Tripping characteristics
I
5
1
n
10’000
2’000
1’000
[ sec ]
500
200
100
0,5
0,3
0,2
0,1
3… 15 A
50
20
10
5
2
1
1,05
Multiple of rated current
1,32
Type
Rated current
Ambient temp.
2
Connectors
3
Wiring
0 Without
1 With
2 Special (on request)
0 Without line filter
0 Without line filter
[ x I n ]
4
5
TA45
I ≥ 3... ≤ 15 A
1-pole protected
2-pole protected
+23 °C
n
* Temperature must be measured at the rear of the breaker next to
the terminals after equipment operating temperature has been
reached.
1)
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+ 40 °C ambient temperature
Example
8
10
www.schurter.com/pg05
6 A x 1,08 = 6,5 A
645
+40 °C
6,0 A
1,08
5

Related parts for 6145.0031.001