MAX1303BEUP+ Maxim Integrated Products, MAX1303BEUP+ Datasheet - Page 23

no-image

MAX1303BEUP+

Manufacturer Part Number
MAX1303BEUP+
Description
ADC Single SAR 115KSPS 16-Bit Serial 20-Pin TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1303BEUP+

Package
20TSSOP
Resolution
16 Bit
Sampling Rate
115 KSPS
Architecture
SAR
Number Of Adcs
1
Number Of Analog Inputs
4|2
Digital Interface Type
Serial (SPI, QSPI, Microwire)
Input Type
Voltage
Signal To Noise Ratio
90(Typ) dB
Polarity Of Input Voltage
Unipolar|Bipolar
Figure 15. Analog Input Configuration Byte and Mode-Control Byte Timing
Figure 16. DOUT and SSTRB Timing
Table 7. Mode-Control Byte
BIT NUMBER
DOUT
SCLK
NOTE: SSTRB AND CS REMAIN LOW IN EXTERNAL CLOCK MODE (MODE 0).
DIN
CS
• User supplies one byte of SCLK, then drives CS
• After SSTRB transitions high, the user supplies
7
6
5
4
3
2
1
0
IMPEDANCE
high to relieve processor load while the ADC
converts
two bytes of SCLK and reads data at DOUT
t
t
DV
CSS
HIGH
t
DS
SSTRB
DOUT
SCLK
CS
START
t
SSCS
1
HIGH IMPEDANCE
BIT NAME
______________________________________________________________________________________
START
t
CL
M2
M1
M0
SEL2
1
0
0
0
t
CSS
8-/4-Channel, ±V
ANALOG INPUT CONFIGURATION BYTE
SEL1
t
DO
Start Bit. The first logic 1 after CS goes low defines the beginning of the mode-control byte.
Mode-Control Bits. M[2:0] select the mode of operation as shown in Table 8.
Bit 3 must be a logic 1 for the mode-control byte.
Bit 2 must be a logic 0 for the mode-control byte.
Bit 1 must be a logic 0 for the mode-control byte.
Bit 0 must be a logic 0 for the mode-control byte.
SEL0
MSB
t
CP
DIF/SGL
t
CH
R2
R1
t
CSH
R0
t
t
8
DH
TR
IMPEDANCE
HIGH
The MAX1302/MAX1303’s fastest maximum throughput
rate is achieved operating in external clock mode.
SCLK controls both the acquisition and conversion of
the analog signal, facilitating precise control over when
the analog signal is captured. The analog input sam-
pling instant is at the falling edge of the 14th SCLK
(Figure 2).
Since SCLK drives the conversion in external clock
mode, the SCLK frequency should remain constant
while the conversion is clocked. The minimum SCLK
frequency prevents droop in the internal sampling
capacitor voltages during conversion.
SSTRB remains low in the external clock mode, and as a
result may be left unconnected if the MAX1302/
MAX1303 will always be used in the external clock mode.
REF
t
CSPW
START
DESCRIPTION
1
M2
Serial 16-Bit ADCs
Multirange Inputs,
M1
MODE CONTROL BYTE
M0
External Clock Mode (Mode 0)
1
0
0
0
8
IMPEDANCE
HIGH
23

Related parts for MAX1303BEUP+