KMS1524 TDK Corporation, KMS1524 Datasheet - Page 13

no-image

KMS1524

Manufacturer Part Number
KMS1524
Description
AC/DC Power Supply Single-OUT 24V 0.62A 15W 4-Pin
Manufacturer
TDK Corporation
Datasheet

Specifications of KMS1524

Input Voltage
100 to 240 V
Output Voltage
24 V
Maximum Current Rating
0.8 A
Maximum Output Current
0.62 A
Number Of Outputs
1
Maximum Output Power
15 W
Input Frequency
47 to 63 Hz
Operating Temperature
-25 to 70 °C
Special Instructions for medical applications (IEC/EN/UL/CSA 60601-1)
These products are designed for continuous operation within an overall enclosure, and must be mounted
such that access to the mains terminals is restricted. See clause 16, IEC60601-1, EN60601-1 and UL/CSA
60601-1.
Input Connection - KMx15 –xx
These products are NOT suitable for use in the presence of flammable anaesthetic mixtures with air or with
oxygen, or with nitrous oxide.
These products are classed as ordinary equipment, type B and have a reinforced barrier between input and
output to IEC60601-1, EN60601-1 and UL/CSA 60601-1. They are NOT protected against the ingress of
water.
Reference should be made to local regulations concerning the disposal of these products at the end of their
useful life.
Environmental Specifications:
1
2
3
4
5
6
7
8
9
Overvoltage Category
Product HANDBOOK
Pollution Degree
Pin
Material Group
Temperature
Description
Orientation
Pressure
Humidity
Vibration
Altitude
Shock
Class
Use
No pin
AC (L)
AC (N)
-DC out
No pin
No pin
+DC out
No pin
No pin
Single O/P
-25° C - +70° C (derating at 2.5%/° C above 50° C)
No Pin
AC (L)
AC (N)
-DC out
GND
No pin
+DC out
No pin
No pin
Dual O/P
20 - 95% RH, non-condensing
23.52m/s
KM15 Series
No Pin
AC (L)
AC (N)
GND for +5V
+5V
-DC out
No pin
GND
+DC out
70kPa - 106kPa
-200m - 3000m
Triple O/P
Operation
2
Indoor
(10-55Hz): constant sweep 1min X, Y, Z for 1 hour
<196.1m/s
IIIb
2
II
II
2
(20G)
20 - 95% RH, non-
54kPa - 106kPa
-40° C - +100°C
-200m - 5000m
condensing
Storage
ALL
-

Related parts for KMS1524