LPS50-M Series 60 Watts Total Power Watts Input Voltage 264 VAC 127 - 300 VDC # of Outputs: Single Special Features • Medical Safety Approvals • Universal input • Less than 1U high • 2” x 4” footprint • Remote sense • Overload and short circuit protection • Adjustable output voltage • High efficiency • High MTBF • Built in EMI filter (CISPR 22 Class B) • LED power good indicator • Input power < 74 watts • Complies with EN61000 -3-2 • UL Class I approved • LPX50 enclosure kit available • Dual AC fuses Safety UL 60601-1 ...
Page 2
Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -40 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 95% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Mechanical Drawing M1 GRN DB1 YEL TP1 GND SK1 T3.15A 2. 250VAC 2005 0.197” (5.0) Minimum ...
Page 3
... Maximum Load with Peak Regulation Convection Cooling Load ± 5.4 A ± 4.4 A ±2% 2.5 A 2.75 A ±2% 1.25 A 1.35 A ±2% LPS54-M LPS55-M LPS58-M Line Line Line Neutral Neutral Neutral +15 V +24 V +48 V +15 V +24 V +48 V Common Common Common Common Common Common -Sense -Sense ...