Specifications of DLP240241/E

Input Voltage
85 to 265 V
Output Voltage
24 V
Maximum Current Rating
3 A
Maximum Output Current
10 A
Number Of Outputs
1
Maximum Output Power
240 W
Efficiency
86 %
Input Frequency
47 to 63 Hz
Operating Temperature
-10 to 70 °C
Voltage - Output
24V
Power (watts)
240W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 10A
Size / Dimension
4.33" L x 4.72" W x 3.82" H (110mm x 120mm x 97mm)
Power (watts) - Rated
240W
Approvals
CE, CSA, EN, IEC, UL
Brand/series
DLP Series
Configuration
Enclosed
Current, Inrush
20 A (Typ.) @ 100 VAC⁄45 A (Typ.) @ 230 VAC
Current, Rating
3.0 A @ 100 VAC⁄1.3 A @ 230 VAC
Frequency
47 to 63 Hz
Height
110 mm
Operation
Linear
Output
24 VDC @ 10 A
Power, Output
240 W
Primary Type
AC-DC
Special Features
PFC
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-10 °C
Voltage, Input
85 to 265/120 to 370 VAC/VDC
Voltage, Output
24 VDC
Voltage, Rating
85 to 265 VAC⁄120 to 370 VDC
Width
97 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1209
DLP240-24-1/E
CA736-01-01C
This specifications sheet also apply to option model /E,/EJ
* Read instruction manual carefully , before using the power supply unit.
* 1 : At 100/230VAC and maximum output power, Ta = 25°C.
* 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as
* 3 : Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
* 4 : Please refer to Fig A for measurement of line & load regulation and output ripple voltage.
* 5 : 85 - 265VAC, constant load.
* 6 : No load - Full load(Maximum power), constant input voltage.
* 7 : Constant current limit with automatic recovery.
* 8 : OVP circuit will shutdown output, manual reset. (Re power on)
* 9 : Measured by each measuring method of UL, CSA, EN and
*10: At standard mounting method, Fig B.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
1
2
3
4
5
6
7
8
9
Nominal Output Voltage
Maximum Output Current
Maximum Output Power
Efficiency
Input Voltage Range
Input Current
Inrush Current
PFHC
Power Factor (Typ)
Output Voltage Range
Maximum Ripple & Noise
Maximum Line Regulation
Maximum Load Regulation
Temperature Coefficient
Over Current Protection
Over Voltage Protection
Hold-Up Time
Leakage current
Parallel Operation
Series Operation
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration
Shock (In package)
Safety
EMI
Immunity
Weight (Typ)
Size ( W.H.D.)
- Load(%) is percent of maximum output load ( Item2 and 3 ), do
-For standard mounting, refer to derating curve (CA736-01-02_)
(Measure with JEITA RC-9131 probe)
100 - 240VAC, 50 / 60Hz on name plate.
Avoid to operate at overload or dead short for more than 30seconds.
DENAN (at 60Hz).
ITEMS
not exceed derating in both Maximum Output Current and Power.
= NOTES=
( * 4 )
(100/230VAC) (Typ)
(100/230VAC) (Typ)
(100/230VAC)
(100/230VAC) (Typ)
-10 Ta<0°C
0 Ta 60°C
( * 4, 5 ) mV
( * 4, 6 ) mV
DLP240-24-1 SPECIFICATIONS
( * 10 )
( * 1 ) %
( * 2 )
( * 1 ) A
( * 3 )
( * 1 )
( * 7 ) A
( * 8 ) V
( * 1 )
( * 9 )
MODE
mm
mV
mV
W
V
V
A
g
170VAC~265VAC :- 10 ~ + 70 °C , Convection: -10 ~ +55°C ( 100% ); 70°C ( 60% )
85VAC~170VAC :- 10 ~ + 60 °C , Convection: -10 ~ +50°C ( 100% ); 60°C ( 60% )
EN60529 IP20, EN50178 CATEGORY III(Primary), Built to meet DENAN
Approved by UL60950, CSA60950, EN60950, UL508, CSA C22.2 No14,
More than 100M
Input - Output : 3.0kVAC, Input - FG : 2.0kVAC (20mA) for 1min
10~55Hz(Sweep for 1min) 9.8m/s
Built to meet IEC61000-6-2 (IEC61000-4-2,-3,-4,-5,-6,-8,-11)
Output
terminal
Built to meet VCCI-B, FCC-ClassB, EN55011/EN55022-B
Measurement point for
Vo Line/Load Regulation.
20A at 100VAC, 45A at 230VAC, Ta=25
85 ~ 265VAC (47-63Hz) or 120 ~ 370VDC
Output - FG : 500VAC (100mA) for 1min.
120x97x110 (Refer to Outline Drawing)
At no operating and with DIN RAIL
+V
-V
at Ta=25°C and 70%RH, Output - FG : 500VDC
Built to meet IEC61000-3-2
30 ~ 90 %RH (No dewdrop)
10 ~ 95%RH (No dewdrop)
Convection cooling
Less than 0.05%/°C
Less than 0.75mA
Less than 196m/s
DLP240-24-1
- 30 ~ +85°C
20ms /30ms
L
30.0~35.0
0.99 / 0.95
21.6~28
Possible
3.0/1.3
82/86
10.5~
1000
240
240
360
120
192
24
10
-
2
Measurement point
for Vripple
Constant, X, Y, Z each 1hour
Output terminal
2
+
C1 C2
o
C, Cold Start
A
DENSEI-LAMBDA
C1 : Elec. Cap 100uF
C2 : Film Cap 0.1uF
Bandwidth of scope : 100MHz
L : 150mm
Input terminal
Fig. A
Rail
Fig.B

Related parts for DLP240241/E

DLP240241/E Summary of contents

Page 1

CA736-01-01C This specifications sheet also apply to option model /E,/EJ ITEMS Nominal Output Voltage 1 Maximum Output Current 2 Maximum Output Power 3 4 Efficiency (100/230VAC) (Typ) Input Voltage Range 5 Input Current (100/230VAC) (Typ) 6 Inrush Current (100/230VAC) (Typ) ...

Page 2

DLP240-24-1 OUTPUT DERATING CA736-01-02 (This specifications sheet also apply to option model /E,/EJ) *COOLING: CONVECTION COOLING OUTPUT DERATING CURVE 100 -10 0 DLP240-24-1 MOUNTING: STANDARD MOUNTING LOADING CONDITION(%) 85VAC~170VAC Ta(°C) 100 -10~ ...

Related keywords