CC109114402 Lineage Power, CC109114402 Datasheet - Page 5

no-image

CC109114402

Manufacturer Part Number
CC109114402
Description
Module DC-DC 1-OUT 5V 20A 8-Pin 1/8-Brick
Manufacturer
Lineage Power
Type
Step Downr
Datasheet

Specifications of CC109114402

Package
81/8-Brick
Output Current
20 A
Output Voltage
5 V
Input Voltage
48 V
Number Of Outputs
1
Data Sheet
September 21, 2010
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
* Note: 12.0V
when a 12V
to normal; or 2) toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, T
as specified for All Devices, will occur whenever a 12V
12.0V
LINEAGE
Parameter
Remote On/Off Signal Interface
Turn-On Delay and Rise Times
(I
from instant at which V
Output voltage overshoot – Startup
I
Remote Sense Range
(Max voltage drop is 0.5V)
Output Voltage Adjustment Range
Output Overvoltage Protection
Input Undervoltage Lockout
Input Overvoltage Lockout
O
Case 1: On/Off input is set to Logic Low (Module
ON) and then input power is applied (T
instant at which V
Case 2: Input power is applied for at least 1 second
and then the On/Off input is set from OFF to ON (T
Output voltage Rise time (time for Vo to rise from 10%
of V
Output voltage Rise time (time for Vo to rise from 10%
of V
O
(V
Signal referenced to V
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
= I
=I
Turn-on Threshold
Turn-off Threshold
Hysterisis
Turn-on Threshold
Turn-off Threshold
Hysterisis
Logic Low - Remote On/Off Current
Logic Low - On/Off Voltage
Logic High Voltage – (Typ = Open Collector)
Logic High maximum allowable leakage current
O
IN
O, max
O, max ,
(B) also achieves +10% V
=V
o,set
o,set
IN, min
to 90% of V
to 90% of V
; V
O
V
O
module restarts following either 1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout and then back
POWER
IN
IN
(B) device codes have an adaptable extended Turn-On Delay interval, T
=V
=V
to V
IN, nom,
IN, min
IN, max
IN
o, set
o, set
to V
= V
T
; open collector or equivalent,
IN
A
)
IN-
=V
= 25
with max ext capacitance)
IN, max
IN, min
terminal)
IN, min
O, set
o
, T
until Vo=10% of V
C)
Remote Sense drop or trim up to 110% V
until V
A
36 – 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current
= 25
O
o
C
delay
= 10% of V
from
O
module restarts with input voltage removed from the module for the preceding 1 second.
O,set
O, set
)
delay
).
=
P, S1R0
G, Y, M,
B*, A, F
Device
S1R0
All*
All
All
All
All
All
B*
All
B*
All
All
All
All
All
G
M
B
A
F
Y
P
O, set
only above Vin = 40V
Symbol
delay
V
V
V
V
V
V
V
V
V
V
V
V
V
V
T
T
T
T
I
I
T
T
SENSE
SENSE
on/off
on/off
O, limit
O, limit
O, limit
O, limit
O, limit
O, limit
O, limit
O, limit
UVLO
OVLO
on/off
on/off
delay
delay
delay
delay
rise
rise
, as specified for B* devices. The extended T
EQW010-040 Series Power Modules
Min
-0.7
5.7
3.8
2.9
2.3
1.8
1.4
1.2
1.5
80
14
30
30
75
2
dc
.
34.5
Typ
3.5
10
25
25
32
80
79
5
8
8
2
Max
0.25
110
1.0
1.2
6.5
4.6
3.4
2.6
2.2
1.6
1.4
10
20
30
10
30
12
12
10
16
36
83
5
3
delay
will occur
% V
% V
% V
msec
msec
msec
msec
msec
msec
delay
Unit
Vdc
mA
V
V
μA
V
V
V
V
V
V
V
V
V
V
V
V
V
V
dc
dc
dc
dc
dc
dc
dc
dc
dc
dc
dc
dc
dc
dc
dc
dc
O, set
O, set
O, set
,
5

Related parts for CC109114402