BQ1101-7 POWER ONE, BQ1101-7 Datasheet
BQ1101-7
Specifications of BQ1101-7
Related parts for BQ1101-7
BQ1101-7 Summary of contents
Page 1
U 164 20 6.5" 0.8" Description These extremely compact DC-DC converters incorporate all necessary input and output filtering, signaling, and protection features, which are required in the majority of applications. The converters provide important ...
Page 2
... Q Series Data Sheet 66 – 132 Watt DC-DC Converter Operating input voltage range, efficiency η η η η η η η η η η – – min i max min i min i max BQ1101-9 81* GQ1101-9 BQ1001-9R 85 GQ1001-9R 85.5 - B1, G BQ2320-9R 86 GQ2320-9R BQ2540-9R 87 GQ2540-9R 86.5 - B1, G BQ2660-9R ...
Page 3
Part Number Description Input voltage range 14.4 – ....................................................... B 21.6 – ....................................................... G 33.6 – ........................................................ C 38.4 – ..................................................... 48 43 – 108 V ......................................................... D ...
Page 4
Product Marking Type designation, applicable safety approval and recognition marks, CE mark, warnings, pin allocation, Power-One patents, and company logo. Identification of LEDs, test sockets, and potentiometer. Input voltage range and input current, nominal output voltages and currents, degree ...
Page 5
Functional Description The converters are designed as forward converters using primary and secondary control circuits in SMD technology. The switching frequency is approximately 200 kHz under nominal operating conditions. The built-in high-efficient input filter together with a small input ...
Page 6
Electrical Input Data General Conditions: – °C, unless T is specified – Sense lines connected directly at the connector, inhibit (28) connected to Vi – (32). – R input not connected; with option P, ...
Page 7
Input Fuse An incorporated fuse in series to the negative input line protects against severe defects. The fuse is not externally accessible. Reverse polarity at the input will cause the fuse to blow. Table 3: Fuse specifications Model Fuse ...
Page 8
Electrical Output Data General Conditions: – °C, unless T is specified – Sense lines connected directly at the connector, inhibit (28) connected to Vi – (32). – R input not connected; with option P, ...
Page 9
Table 5b: Output data for double-output models with both outputs in parallel configuration. General conditions as per table 5a Output Characteristics st V Setting voltage of 1 output o1 V Worstcase output voltage ow V Overvoltage limitation o P ...
Page 10
Table 6a: Output data for double-output models with output 1 and output 2 in symmetrical or independent configuration. General conditions as per table 5a. Output Characteristics Conditions 1 V Output setting voltage nom V ...
Page 11
Table 6b: Output data for double-output models with output 1 and output 2 in symmetrical or independent configuration. General conditions as per table 5a Output Characteristics Conditions 1 V Output setting voltage nom V ...
Page 12
Parallel and Series Connection Single- or double-output models with equal output voltage can be connected in parallel without any precaution by inter- connecting the T-pins for equal current sharing; see fig. 9a. Double-output models with their outputs connected in ...
Page 13
Redundant Configuration Fig. 10a shows a circuit with ORing diodes D output lines, forming a redundant configuration. For accurate output voltage regulation, the sense lines are connected after the ORing diodes. The T pins should be connected together to ...
Page 14
Note: If output 2 is not used, we recommend to connect it in parallel to Vo1. This results in improved efficiency and stability max ...
Page 15
Current distribution in overload is dependent upon the type of overload. A short-circuit in one output will cause the full current flow into that output, whereas a resistive overload results in more even distribution and in a reduced output ...
Page 16
Auxiliary Functions Inhibit for Remote On/Off Note: If this function is not used, the inhibit pin 28 must be connected with pin 32 to enable the output(s). A non- connected pin 28 will be interpreted by the internal logic ...
Page 17
Programmable Output Voltage (R-Function) This feature is not available on models with 3.3 V output or with option P. Note: Models with 3.3 V output or with option P: The R-input must be left open-circuit. The converters offer a ...
Page 18
Output Good Signal (Out-OK) The isolated Out-OK output gives a status indication of the converter and the output voltage. It can be used for control functions such as data protection, central system monitoring part of a ...
Page 19
Electromagnetic Compatibility (EMC) A metal oxide VDR together with an input fuse and a symmetrical input filter form an effective protection against Electromagnetic Immunity Table 13: Immunity type tests Phenomenon Standard Level Supply related RIA 12 B surge EN ...
Page 20
Electromagnetic Emissions Table 14: Emissions at V and I i nom o nom Model Class accord 55011 and EN 55022 Conducted 0.15 – 30 MHz Radiated 30 – 1000 MHz BQ B 48Q / ...
Page 21
Immunity to Environmental Conditions Table 15: Mechanical and climatic stress Test method Standard Cab Damp heat IEC/EN 60068-2-78 steady state MIL-STD-810D section 507.2 Kb Salt mist, cyclic IEC/EN 60068-2-52 (sodium chloride NaCl solution) Fc Vibration IEC/EN 60068-2-6 (sinusoidal) MIL-STD-810D ...
Page 22
Mechanical Data The converters are designed to be inserted into a 19" rack according to IEC 60297-3. Dimensions are in mm. Fig. 25 Case Q 01, weight approx. 500 g Aluminium, fully enclosed, black finish, and self cooling Notes: ...
Page 23
Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 connector. Pin no. 26, the protective earth pin leading pin, ensuring that it ...
Page 24
Table 19: Isolation Characteristic Factory test ≥1 s Electric strength AC test voltage equivalent tests to factory test Insulation resistance Minimum creepage distances * Models with version V104 or higher. Older converters have only been tested with 0.3 kVDC. ...
Page 25
Table 21: Safety concept leading to an SELV output circuit Conditions Front end Nominal Minimum required grade supply of insolation pro- voltage vided by the AC-DC front end, including mains- supplied battery charger Mains Functional (i.e. there ...
Page 26
Accessories A great variety of electrical and mechanical accessories are available: • Various mating connectors including fast-on, screw, solder or press-fit terminals, code key system • Connector retention brackets CRB-Q [HZZ01217] • Cable connector housing (cable hood) KSG-H15/H15S4 [HZZ00141], ...