CC109130507 Lineage Power, CC109130507 Datasheet - Page 17

no-image

CC109130507

Manufacturer Part Number
CC109130507
Description
Module DC-DC 1-OUT 0.6V to 3.63V 20A 10-Pin SMT T/R
Manufacturer
Lineage Power
Datasheet
Data Sheet
April 7, 2011
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 45. The preferred airflow direction
for the module is shown in Figure 46.
LINEAGE
Wind Tunnel
PWBs
Figure 45. Thermal Test Setup.
POWER
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 20A output current
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
TLynx
The thermal reference points, T
specifications are shown in Figure 46. For reliable
operation the temperatures at these points should not
exceed 125
not exceed the rated power of the module (Vo,set x
Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
Figure 46. Preferred airflow direction and location of
hot-spot of the module (Tref).
TM
: Non-isolated DC-DC Power Modules:
o
C. The output power of the module should
ref
used in the