Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should
always be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-
up is shown in Figure 60. The preferred airflow
direction for the module is in Figure 61.
The thermal reference points, T
specifications are also shown in Figure 60. For
reliable operation the temperatures at these points
should not exceed 120
module should not exceed the rated power of the
module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Wind Tunnel
PWBs
Figure 60. Thermal Test Setup.
POWER
o
C. The output power of the
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
ref
8 – 16Vdc input; 0.6Vdc to 8.0Vdc output; 4A output current
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
used in the
16V Pico TLynx
TM
Figure 61. Preferred airflow direction and location
of hot-spot of the module (Tref).