n
n
n
n
n
n
n
Typical applications
Universal use in control and automation
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
Limiting making current, max. 20ms
Limiting breaking current
Limiting short-time current
Switching power
Contact material
Min. recommended contact load
Initial voltage drop
Frequency of operation
Approvals
VDE REG.-Nr. 115719, cULus E214025, Lloyds 00/20059(E2)
Technical data of approved types on request
Contact Data
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
Operate time typ., DC coil
Release time typ., DC coil, without/with PD
Bounce time typ., DC coil, form A/form B
Contact ratings
Type
IEC 61810
PT 2 DC/AC coil
PT 2 DC/AC coil
PT 2 DC/AC coil
PT 3 DC/AC coil
PT 5 DC/AC coil
2 pole 12A, 3 pole 10A or 4 pole 6A, 2, 3 or 4 form C (CO) contacts
DC or AC coil
Switching performance up to 3000VA
Relay height 29mm
Mechanical indicator, optional LED and protection diode
Manual test tab, optionally lockable
White marking tabs
with/without load
Contact
C (CO)
A (NO) of C (CO) 9A, 250VAC, cosφ=1, 80°C
A (NO) of C (CO) 4A, 250VAC, cosφ=1, 80°C
C (CO)
C (CO)
Load
12A, 250VAC, cosφ=1, 70°C
10A, 250VAC, cosφ=1, 70°C
6A, 250VAC, cosφ=1, 70°C
2 form C
400VAC
3000VA
General Purpose Relays
Industrial Relays
Miniature Relay PT
AgNi90/10, AgNi90/10 gold plated
2 CO
PT2
12A
24A
12A
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
gold plated: 20mV at 1mA
30mV at 100mA/6VDC
360/36000h
12V at 10mA
300A/30ms
3 form C
10/18ms
240VAC
400VAC
2500VA
6/8ms
15ms
3 CO
PT3
10A
20A
10A
-1
4 form C
240VAC
1500VA
4 CO
PT5
12A
6A
6A
150x10
300x10
100x10
100x10
70x10
Cycles
3
3
3
3
3
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
Contact Data
Contact ratings
Type
UL 508
PT 2
PT 2
PT 2
PT 2
PT 3
PT 3
PT 3
PT 3
PT 5
PT 5
PT 5
PT 5
EN60947-4-1
PT 2
PT 2
PT 3
PT 3
PT 5
PT 5
Mechanical endurance
Coil Data
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL
DC coil
AC coil
DC coil, AC-coil 50Hz
AC coil 60 Hz at 70°C
Contact
C (CO)
C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
C (CO)
C (CO)
A (NO) of C (CO)
B (NC) of C (CO)
C (CO)
C (CO)
A (NO) of C (CO)
B (NC) of C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
A (NO) of C (CO)
(continued)
Load
12A, 250VAC, general purpose, 70°C
12A, 250VAC, resistive, 70°C
12A, 250VAC, resistive, 70°C
12A, 250VAC, resistive, 70°C
10A, 250VAC, general purpose, 70°C
10A, 250VAC, resistive, 70°C
10A, 250VAC, resistive, 70°C
10A, 250VAC, resistive, 70°C
6A, 250VAC, general purpose, 70°C
6A, 250VAC, resistive, 70°C
6A, 250VAC, resistive, 70°C
6A, 250VAC, resistive, 70°C
400VAC, 3.75A, AC3, opposite polarity, 70°C
230VAC, 1.7A, AC5b (400W lamp load),
opposite polarity, 70°C
250VAC, 2A, AC3, opposite polarity 70°C
230VAC, 1.7A, AC5b (400W lamp load),
opposite polarity, 70°C
250VAC, 3A, AC3, same polarity 70°C
230VAC, 1.7A, AC5b (400W lamp load),
same polarity, 70°C
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
90..110% of rated voltage
30x10
20x10
6 to 220VDC
6 to 230VAC
class 155 (F)
6
6
operations
operations
2
V
Schrack
Z L
F0191-B
100x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
100x10
Cycles
6.000
6.000
6.000
3
3
3
3
3
3
3
3
3
1