SI2434-C-FTR Silicon Laboratories Inc, SI2434-C-FTR Datasheet - Page 40

no-image

SI2434-C-FTR

Manufacturer Part Number
SI2434-C-FTR
Description
Modem Chip Chipset 33.6Kbps 24-Pin TSSOP T/R
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI2434-C-FTR

Package
24TSSOP
Main Category
Chipset
Sub-category
ISOmodem
Maximum Data Rate
33.6 Kbps
Typical Operating Supply Voltage
3.3 V
Power Supply Type
Digital
Typical Supply Current
26 mA
Minimum Operating Supply Voltage
3 V
Maximum Operating Supply Voltage
3.6 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SI2434-C-FTR
Quantity:
2 069
Si2457/34/15/04
40
S-Register
(Decimal)
24
30
38
40
41
Sleep Inactivity Time—Sets the time that the modem
operates in normal power mode with no activity on the
serial port, parallel port, or telephone line before enter-
ing low-power sleep mode. This feature is disabled if
the timer is set to 0.
Disconnect Activity Timer—Sets the length of time that
the modem stays online before disconnecting with no
activity on the serial port, parallel port, or telephone
line (Ring, hookswitch flash, or caller ID). This feature
is disabled if set to 0.
Hang Up Delay Time—Maximum delay between
receipt of ATH0 command and hang up. If time out
occurs before all data can be sent, the NO CARRIER
(3) result code is sent (operates in V.42 mode only).
“OK” response is sent if all data is transmitted before
timeout. S38 = 255 disables timeout and modem dis-
connects only if data is successfully sent or carrier is
lost.
Data Pattern—Data pattern generated during &T4 and
&T5 transmit tests.
0 = All spaces (0s)
1 = All marks (1s)
2 = Random data
V.34 symbol rate - Symbol rate for V.34 when using the
&T4 and &T5 commands.
0 = 2400
1 = 2743
2 = 2800
3 = 3000
4 = 3200
5 = 3429
A valid combination of symbol rate (S41) and data rate
(&G) must be selected.
Symbol Rate
2400
2743
2800
3000
3200
3429
symbols/second
symbols/second
symbols/second
symbols/second
symbols/second
symbols/second
Table 15. S-Register Description (Continued)
Allowable Data Rates
2400–21600
4800–26400
4800–26400
4800–28800
4800–31200
4800–33600
Function
Definition
Rev. 1.1
(Decimal)
Default
20
0
0
0
0
Range
0–255
0–255
0–255
0–2
0–5
seconds
seconds
minutes
Units