MAX7032ATJ+T Maxim Integrated Products, MAX7032ATJ+T Datasheet - Page 23

no-image

MAX7032ATJ+T

Manufacturer Part Number
MAX7032ATJ+T
Description
RF Receiver IC TRASCEIVER ASK/FSK
Manufacturer
Maxim Integrated Products
Type
Transceiverr
Datasheet

Specifications of MAX7032ATJ+T

Package / Case
TQFN-32 EP
Operating Frequency
450 MHz
Operating Supply Voltage
2.7 V, 5 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 7. Configuration 0 Register (Address: 0x02)
Table 8. Configuration 1 Register (Address: 0x03)
MGAIN
ONPS1
ONPS0
CLKOF
OFPS1
OFPS0
MODE
BIT ID
BIT ID
CDIV1
CDIV0
ACAL
DRX
DT2
DT1
DT0
T/R
X
ASK/FSK Transceiver with Fractional-N PLL
FSK or ASK modulation
Transmit or receive
Manual gain mode
Discontinuous receive
mode
Off-timer prescaler
Off-timer prescaler
On-timer prescaler
On-timer prescaler
None
Automatic FSK calibration
Continuous clock output
(even during t
ENABLE pin is low)
Crystal divider
Crystal divider
AGC dwell timer
AGC dwell timer
AGC dwell timer
Low-Cost, Crystal-Based, Programmable,
______________________________________________________________________________________
BIT NAME
BIT NAME
OFF
or when
BIT LOCATION (0 = LSB)
BIT LOCATION (0 = LSB)
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Not used
1 = Enable automatic FSK calibration when
coming out of the sleep state in DRX mode
0 = Disable automatic FSK calibration
1 = Enable continuous clock output when CKOUT
= 1
0 = Continuous clock output; if CKOUT = 1, clock
output is active during t
ENABLE pin is high (continuous receive mode)
CLKOUT crystal-divider MSB
CLKOUT crystal-divider LSB
AGC dwell timer MSB
AGC dwell timer
AGC dwell timer LSB
1 = Enable FSK for both receive and
transmit
0 = Enable ASK for both receive and
transmit
1 = Enable transmit mode of the
transceiver, regardless the state of pin
T/R
0 = Enable receive mode of the transceiver
when pin T/R = 0
1 = Enable manual-gain mode
0 = Disable manual-gain mode
1 = Enable DRX
0 = Disable DRX
Sets the time base for the off timer (see the
Off Timer (t
Sets the time base for the on timer (see the
On Timer (t
OFF
ON
FUNCTION
) section)
) section)
FUNCTION
ON
(DRX mode) or when
23