U3741BM-M3FL Atmel, U3741BM-M3FL Datasheet - Page 17

RF Receiver UHF Remote Receiver IF BW of 600kHz

U3741BM-M3FL

Manufacturer Part Number
U3741BM-M3FL
Description
RF Receiver UHF Remote Receiver IF BW of 600kHz
Manufacturer
Atmel
Type
RKE Design Kit (U2741B, U3741BM)r
Datasheet

Specifications of U3741BM-M3FL

Package / Case
SOIC-20
Operating Frequency
450 MHz
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 17. Timing Diagram of the OFF Command Via Pin DATA
Figure 18. Timing Diagram of the OFF Command Via Pin ENABLE
Configuration of the
Receiver
4662B–RKE–10/04
data line
DATA (U3741BM)
Serial bi-directional
Out1 (microcontroller)
ENABLE
data line
DATA (U3741BM)
Serial bi-directional
Receiver
on
X
X
X
X
Receiver on
If the receiver is set to polling mode via pin ENABLE, an ‘L’ pulse (T
at that pin. Figure 18 illustrates the timing of that command. After the positive edge of
this pulse, the sleep time T
ENABLE is held to ‘L’. If the receiver is polled exclusively by a microcontroller, T
be programmed to 0 to enable a instantaneous response time. This command is the
faster option than via pin DATA at the cost of an additional connection to the
microcontroller.
The U3741BM receiver is configured via two 12-bit RAM registers called OPMODE and
LIMIT. The registers can be programmed by means of the bi-directional DATA port. If
the register contents have changed due to a voltage drop, this condition is indicated by a
certain output pattern called reset marker (RM). The receiver must be reprogrammed in
that case. After a power-on reset (POR), the registers are set to default mode. If the
receiver is operated in default mode, there is no need to program the registers.
Table 3 on page 18 shows the structure of the registers. According to Table 2 on page
18, bit 1 defines if the receiver is set back to polling mode via the OFF command, (see
section “Receiving Mode” on page 15) or if it is programmed. Bit 2 represents the regis-
ter address. It selects the appropriate register to be programmed.
t1
OFF command
toff
t2
T
Doze
t3
(Start bit)
t4
Bit 1
("1")
t10
t5
t7
Sleep
T
Sleep
elapses. The receiver remains in sleep mode as long as
T
Sleep
Startup mode
X
X
Startup mode
Doze
U3741BM
X
X
) must be issued
Sleep
can
17