78M6613 PSU Board User Manual
1.3 Safety and ESD Notes
Do not connect test equipment, ICE emulators or external development boards directly to the
78M6613 hardware. Damage to the 78M6613 and external equipment will occur due to the
78M6613’s “high side” reference topology. The 78M6613’s V3P3 (i.e. “high side”) is connected
directly to Neutral (Earth Ground) creating a ground reference disparity with any properly
grounded external equipment.
1.4 Firmware Demo Code Introduction
The Firmware Demo Code provides the following features:
The following setup is used to facilitate performance evaluation between the user at the PC host and the
firmware code in the board:
The 78M6613 is shipped with Firmware Demo Code Revision 1.0 or later loaded in the 78M6613 chip and
included on the CD. The code revision can be verified by entering the command >i via the command line
interface. Firmware for the Demo Unit can be updated using either the Teridian TFP2 or an in-circuit
emulator such as the Signum Systems ADM-51 (www.signum.com
The board components and firmware settings are designed to operate with the following nominal AC
electrical ranges:
Voltage
110-240 VAC
1.5 Testing the 78M6613 PSU Board Prior to Shipping
Before every 78M6613 PSU Board is shipped, the following procedures have been performed at the
factory:
6
Basic energy measurement data such as Watts, Volts, current, VAR, VA, phase angle, power factor,
accumulated energy, frequency, date/time, and various alarm statuses.
Control of alarm thresholds, calibration coefficients, temperature compensation, etc.
The CLI through HyperTerminal or comparable terminal emulator on a different operating system. For
information about the CLI, see the 6613_PSU_S1_URT_V1_0 Firmware Description Document.
Full Calibration – Precise energy source equipment is used to calibrate the current and voltage. The
temperature is also calibrated at the same time.
Accuracy Test – This “bench” level test ensures the energy accuracy is within ±0.5%.
Standard ESD precautions must be taken when handling electronic equipment. The
78M6613 contains ESD protected interfaces.
Current
10 mA – 20A
EXERCISE CAUTION WHEN LIVE AC VOLTAGES ARE PRESENT!
Line Frequency
46-64 Hz
)
.