IT 233 Schaffner EMC Inc, IT 233 Datasheet

no-image

IT 233

Manufacturer Part Number
IT 233
Description
Manufacturer
Schaffner EMC Inc
Datasheet

Specifications of IT 233

Primary Voltage (max)
500V
Mounting Style
Through Hole
Lead Style
PC Pin
Pin Count
6
Operating Temp Range
-25C to 70C
Primary Side Inductance
3000uH
Dcr Primary Side Max
800mOhm
Dcr Secondary Side Max
800mOhm
Rise Time (max)
1300ns
Interwinding Capacitance Max
7pF
Turns Ratio
1:1:1
Product Height (mm)
13.7mm
Product Depth (mm)
27mm
Product Length (mm)
22.5mm
Transformer Type
Pulse Transformer
Lead Free Status / RoHS Status
Compliant
Technical specifications
Nominal operating voltage:
Operating frequency:
Ignition currents:
Rise time:
Test voltage:
Max. partial discharge voltage:
Temperature range (operation and storage):
Flammability corresponding to:
IT pulse transformers are designed to offer
you galvanic isolation for transformer coupled
gate drives. The IT series provides negligible
delays and the possibility of voltage scaling.
They are available with single or double
secondary winding for multiple gate drives.
Choosing the IT product line brings you the
rapid availability of a standard gate drive
transformer. A wide selection on turns ratio,
ignition current and voltages are designed to
offer you the desired standard product.
Pulse transformer with double
secondary winding
n
n
n
n
Up to 500V
40kHz max.
500kHz max. for data transmission
0.1 to 1A @ 40°C
0.4 to 4.0µs
U
1.5 x U
-25°C to +70°C (25/70/21)
UL 94V-0 listed materials
Features and benefits
n
n
n
n
n
n
n
p
/50Hz/2s max. according to VDE 110b
Galvanic separation of drive and power
circuit
Voltage resistance up to 4kV
Ignition current up to 1A
Turns ratio up to 3:1:1
Galvanic separation with secondary
winding.
Voltage resistance up to 4kV.
Allows high potential difference voltage
scaling.
Vacuum potting.
Very low partial discharge effects.
PCB through hole mounting.
Custom-specific versions on request.
nom
Pulse transformers
IT series
Approvals
Typical electrical schematic
Typical applications
n
n
n
n
n
n
n
Gate drive circuit
Power supplies
Power converters
Frequency converters
Switching applications
DC/DC converters
Line coupling transformers in high-speed
data transmission
sec.
prim.
sec.

Related parts for IT 233

IT 233 Summary of contents

Page 1

... Test voltage: Max. partial discharge voltage: Temperature range (operation and storage): Flammability corresponding to: IT pulse transformers are designed to offer you galvanic isolation for transformer coupled gate drives. The IT series provides negligible delays and the possibility of voltage scaling. They are available with single or double secondary winding for multiple gate drives ...

Page 2

... IT 243, IT 244, IT 249, IT 253 143, IT 153, IT 154, IT 233, IT 234 Prim Prim Resistance Coupling Input/Output capacitance connections [Ω] [Ω] [pF 1 0.8 0.8 ...

Page 3

... IT 233 IT 234 IT 312 IT 313 IT 314 Tol. 27* 27* 25.5* 25.5* 25.5* ±0.1 22.5* 22.5* 25.5* 25.5* 25.5* ±0.1 13.7 13.7 25* 25* 25* ±0 +1/-0 0.45 ...

Related keywords