GTCA38-601M-R10 Tyco Electronics, GTCA38-601M-R10 Datasheet

Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors 600V 10KA 3POLE

GTCA38-601M-R10

Manufacturer Part Number
GTCA38-601M-R10
Description
Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors 600V 10KA 3POLE
Manufacturer
Tyco Electronics
Series
GTCx38r
Datasheet

Specifications of GTCA38-601M-R10

Peak Pulse Current
10 KA
Dc Breakover Voltage (nominal)
600 V
Number Of Electrodes
3
Termination Style
Axial
Dimensions
8 mm D x 13.4 mm L

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GTCA38-601M-R10-FS2
Manufacturer:
TYCO
Quantity:
11 387
Part Number:
GTCA38-601M-R10-FT
Manufacturer:
SURGING
Quantity:
7 804
Gas Discharge Tubes
© 2008, 2009 Tyco Electronics Corporation. All rights reserved.
Raychem Circuit Protection 8mm 3Pole GDTs
(ceramic gas discharge tubes), are commonly used
to help protect sensitive telecom equipment such
as communication lines, signal lines and data
transmission lines from damage caused by
transient surge voltages that typically result from
lightning
operations.
Raychem Circuit Protection GDTs offer a high
level of surge protection, low capacitance and a
broad array of breakover voltage levels, making
them suitable for applications such as MDF (Main
Distribution Frame) modules, high data-rate
telecom applications (e.g. ADSL, VDSL), and
surge protection on power lines. Raychem Circuit
Protection GDTs can help equipment meet the
most stringent regulatory standards.
Benefits:
• Helps provide overvoltage fault protection against
• Suitable for high-frequency applications
Applications:
• Telecommunications
- MDF modules, xDSL equipment, RF system
high energy surges
protection, antenna, base station
strikes
and
equipment
switching
1
Features:
• 3Pole, 8mm devices
• Broad voltage range from 75V-600V
• Various form factors: surface-mount, leaded, no
• Optional fail-short mechanism on some devices
• Low capacitance and insertion loss
• Crowbar overvoltage protection
• UL 497B recognized
• RoHS compliant
• Devices tested per ITU K.12 recommendations
• Non-radioactive materials
Industrial and consumer electronics, such as
- Surge protectors
- Alarm system
leads
GTCX38-XXXM-R10 Series
Gas Discharge Tubes
Document: SCD 27381
Status: Released
Rev: B
Date: February 19, 2009

Related parts for GTCA38-601M-R10

GTCA38-601M-R10 Summary of contents

Page 1

... Suitable for high-frequency applications Applications: • Telecommunications - MDF modules, xDSL equipment, RF system protection, antenna, base station Gas Discharge Tubes © 2008, 2009 Tyco Electronics Corporation. All rights reserved. GTCX38-XXXM-R10 Series switching Features: • 3Pole, 8mm devices • Broad voltage range from 75V-600V • ...

Page 2

... Impulse Part Number Discharge Current 8x20µs 10 hits GTCX38-XXXM-R10 10kA * Devices <=150V measured @ 50V. Devices >= 500V measured @ 250V Gas Discharge Tubes © 2008, 2009 Tyco Electronics Corporation. All rights reserved. Impulse Sparkover @100 Vµs (V) @1000 Vµs (V) (V) 75 450 550 90 450 550 ...

Page 3

... GTCX38-XXXM-R10 Series GTCX35-XXX-R05 Series Product Dimensions Axial Leaded with- FS (GTCA38-XXXM-R10-FS2) Axial Leaded with- FT (GTCA38-XXXM-R10-FT) Gas Discharge Tubes © 2008, 2009 Tyco Electronics Corporation. All rights reserved. Gas Discharge Tubes DIMENSIONS = MILLIMETERS [INCHES] Axial Leaded with-FS (GTCA38-XXXM-R10-FS) Axial Leaded (GTCA38-XXXM-R10) Document: SCD 27381 ...

Page 4

... GTCX38-XXXM-R10 Series GTCX35-XXX-R05 Series Radial Leaded with- FT (GTCR38-XXXM-R10-FT) Radial Leaded with-FS (GTCR38-XXXM-R10-FS) Gas Discharge Tubes © 2008, 2009 Tyco Electronics Corporation. All rights reserved. Gas Discharge Tubes Radial Leaded with-FS (GTCR38-XXXM-R10-FS2) Radial Leaded (GTCR38-XXXM-R10) Document: SCD 27381 Status: Released 4 Rev: B Date: February 19, 2009 ...

Page 5

... No Leads with-FT (GTCN38-XXXM-R10-FT) Surface-mount (GTCS38-XXXM-R10) Pad Layout – Surface-mount Devices (GTCS38-XXXM-R10 NOM NOM mm: 9.0 4.65 in*: (0.354) (0.183) Gas Discharge Tubes © 2008, 2009 Tyco Electronics Corporation. All rights reserved NOM NOM NOM 4.65 2.5 1.5 (0.183) (0.098) (0.059) 5 Gas Discharge Tubes ...

Page 6

... Soldering Notes: Devices with no leads: non-solderable; suitable for insertion into a magazine clip Materials Information RoHS Compliant Packaging Information Part Description No Leaded: GTCN38-XXXM-R10(-FT) With Leads: GTCA38-XXXM-R10(-FT/-FS(2)) GTCR38-XXXM-R10(-FT/-FS(2)) Surface-mount: GTCS38-XXXM-R10(-FT) Surface-mount (T&R): GTCS38-XXXM-R10-(FT)-2 Part Numbering System Example Part Number: GTCX38-351M-R10-FT/FS/ FS2 GT = Gas Tube ...

Page 7

... This publication supersedes and replaces all information previously supplied. Without expressed or written consent by an officer of Tyco Electronics, Tyco Electronics does not authorize the use of any of its products as components in nuclear facility applications, aerospace critical life support devices or systems. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. Tyco Electronics’ ...