2026-35-C3F Bourns Inc., 2026-35-C3F Datasheet - Page 3

Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors Sparkover100V/s 350V 3 Pole

2026-35-C3F

Manufacturer Part Number
2026-35-C3F
Description
Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors Sparkover100V/s 350V 3 Pole
Manufacturer
Bourns Inc.
Series
2026r
Datasheet

Specifications of 2026-35-C3F

Peak Pulse Current
40 KA
Dc Breakover Voltage (nominal)
35 V
Number Of Electrodes
3
Termination Style
PBC Mount
Failsafe Protection Y/n
Y
Dimensions
8 mm D x 11.2 mm L
Technology
Gas Discharge Tube
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
REV. 04/11
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
Switch-Grade Fail-short Device Shorting Curve 2026-XX-XF
2026 Series - 3-Pole Gas Discharge Tube
30.0
20.0
10.0
5.0
1.0
0.5
0.1
1
ELTGS = Each Line to Ground Simultaneously
NOTE: When using a GDT fail-short device, it is imperative that all components associated and
connected to the GDT with failsafe be tested in their respective completely integrated environment
(finished product) to assure desired operation.
10
Seconds
100
1000

Related parts for 2026-35-C3F