Specifications of GLC50-24G

Output Current (max)
2.1A
Input Voltage
90 to 264V
Output Voltage
24V
Number Of Outputs
1
Output Power (max)
50W
Input Frequency
47 to 63Hz
Efficiency
85%
Screening Level
Commercial
Product Depth (mm)
63.5mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Screw
Pin Count
9
Lead Free Status / RoHS Status
Compliant
Notes:
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. To maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power.
C. Add “G” suffix to model number for RoHS compliant model.
SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. Rev. 1/07.
Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Commercial
Model
GLC50A
GLC50B
GLC50D
GLC50G
GLC50-3.3
GLC50-5
GLC50-12
GLC50-15
GLC50-24
GLC50-28
GLC50-48
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
GLC50 MECHANICAL SPECIFICATIONS
Medical
Model
GLM50A
GLM50B
GLM50 D
GLM50G
GLM50-3.3
GLM50-5
GLM50-12
GLM50-15
GLM50-24
GLM50-28
GLM50-48
Output No.
OPERATING
0 TO 50°C
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
pk
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
1
1
1
1
rms’
0.003 g
2
/Hz
+5.05 V
+5.05 V
+5.05 V
Output
+3.3 V
+12 V
+15 V
+24 V
+12 V
-12 V
-15 V
-12 V
-12 V
3.3 V
5.1 V
12 V
15 V
24 V
28 V
48 V
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
rms’
pk
0.026 g
2
/Hz
Current
2.5 A
0.2 A
2.5 A
0.2 A
1.5 A
0.2 A
2.5 A
0.2 A
4.2 A
3.3 A
2.1 A
1.8 A
1.1 A
4 A
4 A
4 A
4 A
8 A
8 A
A. Units should be allowed to warm up/operate under non-condensing condi-
tions before application of power. derate output current and total output
power by 2.5% per °C above 50°C.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal
axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
Minimum
Load (B)
0.8 A
0.8 A
0.8 A
0.8 A
0.16
0.09
0.05
0.2
0.4
0.2
0.1
OVP Setpoint
18.5 ± 1.5 V
34.5 ± 2.8 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
4.2 ± 0.6 V
4.2 ± 0.6 V
6.2 ± 0.6 V
14 ± 1.1 V
28 ± 2.5 V
54 ± 3.0 V
Noise P-P
120 mV
120 mV
150 mV
150 mV
240 mV
120 mV
120 mV
120 mV
120 mV
150 mV
240 mV
280 mV
480 mV
50 mV
50 mV
50 mV
33 mV
66 mV
75 mV
Regulation (A)
+10%,-5%
+10%,-5%
+10%,-5%
+10%-5%
Total
2%
3%
2%
3%
2%
3%
2%
3%
2%
2%
2%
2%
2%
2%
2%

Related parts for GLC50-24G