LWN1240-6EM1 POWER ONE, LWN1240-6EM1 Datasheet - Page 20

no-image

LWN1240-6EM1

Manufacturer Part Number
LWN1240-6EM1
Description
Manufacturer
POWER ONE
Datasheet

Specifications of LWN1240-6EM1

Input Voltage
85 to 264V
Number Of Outputs
1
Input Frequency
47 to 65Hz
Screening Level
Commercial
Product Length (mm)
138mm
Product Height (mm)
128mm
Product Depth (mm)
113.6mm
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
60C
Mounting Style
Din-Rail
Pin Count
5
Lead Free Status / RoHS Status
Not Compliant
BCD20020-G Rev AB1, 17-Nov-09
Table 14: Isolation
Isolation
The electric strength test is performed in the factory as routine
test in accordance with EN 50116 and IEC/EN 60950 and
should not be repeated in the field. Power-One will not honor
any warranty claims resulting from electric strength field tests.
Leakage Currents in AC-DC Operation
Leakage currents flow due to internal leakage capacitance and
RFI suppression Y-capacitors. The current values are
proportional to the mains voltage and nearly proportional to the
mains frequency. They are specified at maximum operating
input voltage where phase, neutral, and protective earth are
correctly connected as required for class I equipment.
Leakage current may exceed 3.5 mA, if f
Safety of Operator-Accessible Output Circuits
If the output circuit of a converter is operator accessible, it shall
be a SELV circuit according to IEC/EN 60950 related safety
standards.
The converters have SELV output circuits up to an output
voltage of 57.5 V. However, if the isolated outputs are
connected to another voltage source or connected in series
with a total of >57.5 V the outputs are hazardous.
It is the sole responsibility of the installer to ensure the
compliance
regulations.
LED Indicator
A green LED is activated, when the output voltage V
the normal operating tolerance band.
Characteristic
Electric
strength
test
Insulation resistance
1
2
Note: This LED is also activated, when the converter is not
powered by the input, but a loaded battery is connected to the
output.
In accordance with EN 50116 and IEC/EN 60950-1, subassemblies are pretested with 4.2 kVDC.
Tested at 500 VDC.
Factory test 1 s
AC test voltage equivalent
to factory test
with
the
®
relevant
and
i
> 63 Hz.
applicable
and output(s)
Input to case
125, 250 Watt AC-DC and DC-DC DIN-Rail Converters
2.8
300
2.0
o
is within
1
2
safety
Page 20 of 25
Output(s) to
case
300
1.4
1.0
2
output 2 and AUX
Output 1 to
W Series Data Sheet
0.35
0.5
100
www.power-one.com
kVDC
kVAC
Unit
M

Related parts for LWN1240-6EM1