Specifications of MPU200-4530

Output Current (max)
30/15/8/4A
Input Voltage
85 to 264V
Output Voltage
5/3.3/12/12V
Number Of Outputs
4
Output Power (max)
200W
Input Frequency
47 to 63Hz
Efficiency
75%
Screening Level
Commercial
Product Length (mm)
203.2mm
Product Height (mm)
38.1mm
Product Depth (mm)
106.7mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
15
Lead Free Status / RoHS Status
Not Compliant
AC Input, Single-Output Model Selection
MPU200-1012G
MPU200-1024G
MPU200-1048G
AC Input, Multiple-Output Model Selection
MPU200-4530
NOTES: 1) This product is not rated for convection applications.
Description
MCD10010 Rev. 1.1, 27-Jan-10
The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products
incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series,
200 watts of continuous output power is provided with single or multiple output units suited for distributed power or central power
applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital
circuitry.
Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature
remote sense on outputs V1 and V2 to provide independent compensation of output cable losses.
Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote
inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch.
The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 VDC input.
Ordering Information:
OPTIONS
Metric Mounting
Isolation Diode
RoHS lead solder exemption
RoHS compliant for all 6 substances
MODEL
MODEL
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Total current for V1 and V2 is not to exceed 35A.
5) Total power on V3 and V4 is not to exceed 100W.
applied from the input side of the power supply blowing towards the output.
VOLTAGE
OUTPUT
12V
24V
48V
VOLTAGE
OUTPUT
+3.3V
+5V
12V
12V
22.8V to 29.2V
ADJUSTMENT
11.6V to 16V
45V to 56V
RANGE
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
ADJUSTMENT
5.0V to 5.5V
RANGE
CURRENT (NOTE 2)
MAXIMUM OUTPUT
SUFFIXES TO ADD TO PART NUMBER
No RoHS suffix character required.
Add “M” as a suffix to the model number to order chassis with
M3 x 0.7 mounting inserts. Consult factory for availability.
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.
Consult factory for availability.
Add “G” as the last character of the part number.
17.0A
8.35A
4.2A
CURRENT (NOTE 2)
MAXIMUM OUTPUT
30A (Note 4)
15A (Note 4)
8A (Note 5)
4A (Note 5)
PEAK OUTPUT
CURRENT (NOTE 2) REGULATION
Page 1 of 6
19.0A
9.4A
4.7A
Features
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
RoHS lead free solder and lead solder exempted products
are available
Power Factor Correction (PFC) meets EN61000-3-2
Same size, airflow, and construction as MPU150/MDU150
with over 33% more power
Single-wire current sense on quad model outputs V1 and V2
Remote sense on quad model outputs V1 and V2
Current share and N+1 redundancy (standard on all models)
Overtemperature, overload, and overvoltage protection
Available with SAE mountings
MDU200 models have 48 VDC input
REGULATION
0.4%
0.6%
0.4%
0.4%
LINE
MPU200/MDU200 Series Data Sheet
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
0.1%
0.1%
0.1%
LINE
REGULATION
LOAD
1.5%
10%
10%
REGULATION
1%
LOAD
1%
1%
1%
%Pk-Pk (NOTE 3)
RIPPLE & NOISE
RIPPLE & NOISE
%p-p (NOTE 3)
1.5%
1%
1%
1%
1%
1%
1%
www.power-one.com
23.95V to 24.05V
11.97V to 12.03V
11.94V to 12.06V
11.60V to 12.40V
INITIAL SETTING
INITIAL SETTING
47.9V to 48.1V
4.98V to 5.02V
3.28V to 3.32V
ACCURACY
ACCURACY

Related parts for MPU200-4530

MPU200-4530 Summary of contents

Page 1

... MODEL VOLTAGE RANGE +5V 5.0V to 5.5V +3.3V 3.15V to 3.60V MPU200-4530 12V 10.8V to 13.2V 12V 10.8V to 13.2V NOTES: 1) This product is not rated for convection applications. 2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions recommended that the airflow be applied from the input side of the power supply blowing towards the output. ...

Page 2

... Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 4) Derating is required on output voltages above 27VDC. Consult factory. MCD10010 Rev. 1.1, 27-Jan-10 MPU200/MDU200 Series Data Sheet 200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1) MAXIMUM OUTPUT PEAK OUTPUT ...

Page 3

... Inhibit Output voltage is inhibited by application of an external high (5V) signal. MCD10010 Rev. 1.1, 27-Jan-10 MPU200/MDU200 Series Data Sheet Quad output model V1 Single output models V1 Quad output model V3 MPU200 MDU200 MPU200-4530 3.3V output MPU200-4530 5V output MPU200-4530 12V output MDU200/MPU200-1012 V1 MDU200/MPU200-1024 V1 MDU200/MPU200-1048 V1 3.3V 5V MDU200/MPU200-1012 12V ...

Page 4

... M3 x 0.7 mounting inserts. Consult factory for availability. Isolation Diode Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed. Consult factory for availability. MCD10010 Rev. 1.1, 27-Jan-10 MPU200/MDU200 Series Data Sheet (Approved) MPU200 MDU200 MPU200: Line to Line ...

Page 5

... MOLEX CONNECTOR HOUSING SERIES 41695 09-50-8051 J1 41695 09-50-8051 2139 09-50-3051 J300 5264-N 50-37-5103 MCD10010 Rev. 1.1, 27-Jan-10 MPU200/MDU200 Series Data Sheet V1,V. ADJ. 3 PIN PINS PINS WIRE SERIES (LOOSE) (CHAIN) GAUGE 6838 08-50-0189 08-50-0187 18-20AWG 2478 08-50-0106 08-50-0105 18-20AWG 2478 08-50-0106 08-50-0105 18-20AWG ...

Page 6

... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10010 Rev. 1.1, 27-Jan-10 MPU200/MDU200 Series Data Sheet 3 PIN PINS PINS ...

Related keywords