MVLT40-1200LF Red Rocket, MVLT40-1200LF Datasheet - Page 2

no-image

MVLT40-1200LF

Manufacturer Part Number
MVLT40-1200LF
Description
Manufacturer
Red Rocket
Datasheet

Specifications of MVLT40-1200LF

Output Current (max)
8A
Output Voltage
5V
Number Of Outputs
1
Output Power (max)
40W
Input Frequency
47 to 63Hz
Efficiency
82%
Screening Level
Commercial
Product Length (mm)
101.6mm
Product Depth (mm)
50.8mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Screw
Lead Free Status / RoHS Status
Compliant
MVLT40 Series
Medical 40W AC/DC Power Supplies
Operating Temperature
Storage Temperature
All EOS power supplies have UL, CSA and Nemko safety compliance and medical versions meet UL60601-1 standards. All our products are RoHs
compliant. Visit us at www.eospower.com. EOS brand power supplies and patents are owned exclusively by EOS Power. All Rights Reserved.
Relative humidity
ENVIRONMENTAL SPECIFICATION
DC Output connector J2
AC Input Connector J1
Cooling
Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
MTBF
Ground Connector
4EM-10-0xx
OUTPUT CONNECTOR J2
Weight
MECHANICAL SPECIFICATION
Size
Linear derate to 50%
Single Output
MIL - HDBK-217F
Non condensing
Common
Common
No derating
NC
NC
V1
V1
Header 26-60-4030 or equivalent
Header 26-60-4060 or equivalent
Molex 3 position, 0.156 center
Molex 6 position, 0.156 center
101.6 x 50.8 x 27.18 mm
Triple Output
-40 to 70
> 100,000 hrs
4.0 “X 2.0” x 1.07”
Spade connector
51 to 70
Convection
Common
Common
0 to 50
95%, max
5oz (150g)
V1
V1
V3
V2
o
o
o
C
CC
C
EMC AND SAFETY SPECIFICATIONS
Safety file number
Agency Approval
Isolation Voltage
Safety Standard
CE Mark
EMC
Page 2
INPUT SPADE CONNECTOR
INPUT CONNECTOR J1
GND
Pin1
Pin2
EN5022-B,CISPR22-B, FCC
Part 15 Class B, EN50082-1
IEC60601-1, EN60601-1-1,
UL60601-1, CSA C22.2 No
Complies with the LVD
EN60601-1-2ND ED
NEMKO:P06206742
601 Class 1 SELV.
VDE , UL, c-UL
UL: E173812
4000 VAC
AC Ground
AC Neutral
39-DE60-44226-002/A2
AC Line

Related parts for MVLT40-1200LF