PSS 1214-2G POWER ONE, PSS 1214-2G Datasheet
![no-image](/images/manufacturer_photos/0/5/534/power_one_sml.jpg)
PSS 1214-2G
Specifications of PSS 1214-2G
Related parts for PSS 1214-2G
PSS 1214-2G Summary of contents
Page 1
U 60 168 2.4" 6.6" Description The PSS/PSK Series of positive switching regulators is designed as power supplies for electronic systems, where no input-to-output isolation is required. Their major advantages include a high level ...
Page 2
Model Selection Table 1: All models Output Output Operating input Nom. input voltage current voltage range V [V] I [A] o nom o nom 3.3 25 5.1 12 5.1 14 5.1 16 5.1 18 5 ...
Page 3
Part Number Description Positive switching regulator in case S01, K01 ....... PSS, PSK Nominal output voltage in volt .................................... 3.3 Nominal output current in ampere ................................ 9 Operational ambient temperature range T – °C ..................................................... -2 ...
Page 4
Electrical Input Data Table 2a: Input data. General Conditions: T Input Characteristics V Operating input voltage i V Min. diff. voltage V – min Undervoltage lock-out load input current i ...
Page 5
Table 2d: Input data. General Conditions: T Input Characteristics V Operating input voltage i V Min. diff. voltage V – min Undervoltage lock-out load input current Peak ...
Page 6
Electrical Output Data General Conditions: • 25°C, unless T is specified A C • R control (pin 16) not connected or progammed to V • Inhibit input (pin 14) connected to Go– • Sense lines S+ and ...
Page 7
Table 3c: Output data of PSS models. General conditions as per table 3a Output Characteristics V Output voltage o I Output current o I Output current limit oL v Output Switching freq. o voltage Total incl. spikes noise V ...
Page 8
Table 4b: Output data of PSK models. General conditions as per table 3a Output Characteristics Conditions V Output voltage nom I Output current min T C min I Output current limit oL v ...
Page 9
Table 4e: Output data of PSK models. General conditions as per table 3a Output Characteristics V Output voltage o I Output current o I Output current limit oL v Output Switching freq. o voltage Total incl. spikes noise V ...
Page 10
Thermal Considerations and Protection When a switching regulator is located in free, quasi-stationary air (convection cooling temperature T at its nominal output current I , the case temperature T o nom can rise over T after the ...
Page 11
Sense Lines This feature enables compensation of the voltage drop across the connector contacts and the load lines. If the sense lines are connected at the load rather than directly at the connector, the user must ensure that V ...
Page 12
Electromagnetic Compatibility (EMC) Electromagnetic Immunity General condition: Case not earthed. Table 8: Immunity type tests Phenomenon Standard Class Level 2 2 Direct transients IEC 60571-1 2 Electrostatic IEC/ discharge 61000-4 Electromagnetic IEC/ field ...
Page 13
Immunity to Environmental Conditions Table 9: Mechanical and climatic stress Test Method Standard Cab Damp heat IEC/EN 60068-2-78 steady state MIL-STD-810D section 507.2 Ea Shock IEC/EN 60068-2-27 (half-sinusoidal) MIL-STD-810D section 516.3 Eb Bump IEC/EN 60068-2-29 (half-sinusoidal) MIL-STD-810D section 516.3 ...
Page 14
Mechanical Data PSS Models The regulators are designed to be inserted into a rack according to IEC 60297-3. Dimensions in mm. 171.9 50 Measuring point of case temperature T C Front plate Main face 168.5 Fig. 10 Case S ...
Page 15
PSK Models The regulators are designed to be inserted into a rack according to IEC 60297-3. Dimensions in mm. 159 Measuring point of case temperature T 50 171.9 Main face Front plate 168.5 Fig. 11 Case K01 for PSK ...
Page 16
Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 or H15S4 connector. Pin 24 (protective earth leading pin, which provides electrical contact ...
Page 17
Description of Options -9 Extended Temperature Range This option defines an extended temperature range as specified in table 10. P Potentiometer to Adjust the Output Note: Option P is not recommended, if several regulators are operated in parallel connection. ...
Page 18
B, B1 Cooling Plate Where a cooling surface is available, a cooling plate (option B or option B1) can be fitted instead of the standard heatsink. The mounting system must ensure sufficient cooling capacity 5 47.2 38.5 11.8 Fig. ...
Page 19
Accessories A variety of electrical and mechanical accessories are available including: • Various mating connectors H15 and H15S4 including fast- on, screw, solder or press-fit terminals, code key system and coding clips [HZZ00202] • Connector retention brackets CRB [HZZ01216] ...
Page 20
PSx Series switching regulators carrying the CE-mark are in conformity with the provisions of the Low Voltage Directive (LVD) 2006/95 the European Communities.. Conformity with the directive is presumed by ...