24H1001-2R POWER ONE, 24H1001-2R Datasheet - Page 6

24H1001-2R

Manufacturer Part Number
24H1001-2R
Description
Manufacturer
POWER ONE
Datasheet

Specifications of 24H1001-2R

Output Current
8A
Input Voltage
24V
Output Voltage
5.1V
Output Power
50
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Product Length (mm)
173.7mm
Product Depth (mm)
111.2mm
Product Height (mm)
38.7mm
Mounting Style
Din-Rail
Pin Count
11
Number Of Outputs
1
Lead Free Status / RoHS Status
Not Compliant
0.5
Output Protection
Each output is protected against overvoltages which could
occur due to a failure of the internal control circuit. Voltage
suppressor diodes (which under worst case condition may
become a short circuit) provide the required protection. The
suppressor diodes are not designed to withstand externally
applied overvoltages. Overload at any of the outputs will
cause a shut-down of all outputs.
1.0
Parallel and Series Connection
Main outputs of equal nominal voltage can be connected in
parallel. It is important to assure that the main output of a
multiple-output converter is forced to supply a minimum
current of 0.1 A to enable correct operation of its own
auxiliary outputs.
Outputs one and two of a double-output model may be
connected
requirement at the main output. Outputs two and three of a
triple-output model can be connected in parallel.
In parallel operation, one or more of the main outputs may
operate continuously in current limitation which will cause
an increase in case temperature. Consequently, a
reduction of the maximum ambient temperature by 10 K is
recommended.
Main or auxiliary outputs can be connected in series with
any other output of the same or another converter. In series
connection, the maximum output current is limited by the
lowest current limit. Output ripple and regulation values are
added. Connection wiring should be kept as short as
possible.
If output terminals are connected together in order to
establish multi-voltage configurations, e.g. +5.1 V, ±12 V
etc. the common ground connecting point should be as
close as possible to the connector of the converter to avoid
excessive output ripple voltages.
.95
REV. MAR 27, 2006
Fig. 2
Typical output voltage V
V
0
o1 nom
V
o1
in
parallel
0.5
o1
without
versus output currents I
a
I
1.0
o nom
minimum
1.2
I
I
o
oL2
oL1
current
I
I
o2
I
o1
I
o nom
05022
,I
o
,
oL3
I
Page 6 of 19
o3
V
Fig. 3
H2320/H3020: Δ V
Fig. 4
H2540/H3040: Δ V
V
o2/3 0
V
o2/3 0
V
o2/3
o2/3
13
12
11
16
15
14
50 Watt DC-DC Cassette Converters
0
0
[V]
[V]
0.25
0.25
o2/3
o2/3
I
I
o1 nom
(typ.) versus I
(typ.) versus I
o1 nom
0.5
0.5
0.5 • I
0.5 • I
H Series Data Sheet
0.75
0.75
o1 nom
o1 nom
o2/3
o2/3
I
www.power-one.com
I
o1
with different I
with different I
o1
1.0
1.0
= 0 A
= 0 A
I
I
o2/3 nom
o2/3 nom
I
I
o2/3
o1
o1
o2/3
05120
05119

Related parts for 24H1001-2R