KW010A0F41-SR Lineage Power, KW010A0F41-SR Datasheet - Page 7

no-image

KW010A0F41-SR

Manufacturer Part Number
KW010A0F41-SR
Description
DC/DC Converters & Regulators SMT 10A, IN 48V OUT 3.3V NEG
Manufacturer
Lineage Power
Type
Step Downr
Datasheet

Specifications of KW010A0F41-SR

Output Power
33W
Output Current
10A
Input Voltage
48V
Output Voltage
3.3V
Screening Level
Industrial
Product Length (mm)
22.9mm
Product Depth (mm)
33mm
Mounting Style
Surface Mount
Pin Count
8
Number Of Outputs
1
Package / Case
1/16-Brick
Lead Free Status / RoHS Status
Not Compliant
Data Sheet
September 9, 2008
Test Configurations
Figure 13. Input Reflected Ripple Current Test
Setup.
Figure 14. Output Ripple and Noise Test Setup.
Figure 15. Output Voltage and Efficiency Test
Setup.
LINEAGE
NOTE: All voltage measurements to be taken at the module
V
V
O
O
(+)
( – )
Efficiency
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
TO OSCILLOSCOPE
NOTE: Measure input reflected ripple current with a simulated
R
R
NOTE: All voltage measurements to be taken at the module
distribution
distribution
POWER
source inductance (L
possible battery impedance. Measure current as shown
above.
0.1uF
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
COPPER STRIP
R
R
contact
contact
η =
@ 20°C 100kHz
E.S.R.<0.1Ω
C
S
GROUND PLANE
10uF
12μH
L
V
220μF
TEST
IN
V
V
V
V
IN
IN
O
IN
(+)
TEST
(-)
. I
. I
) of 12μH. Capacitor C
O
IN
V
SCOPE
V
OUT
OUT
(+)
(-)
V
x 100 %
O
33μF
36 – 75Vdc Input; 3.3 to 5.0Vdc Output; 6 to 10A Output Current
RESISTIVE
LOAD
CURRENT PROBE
R
R
contact
contact
V
V
S
IN
IN
offsets
(+)
(-)
R
R
distribution
distribution
R
LOAD
Design Considerations
Input Filtering
The power module should be connected to a low
ac-impedance source. Highly inductive source
impedance can affect the stability of the power module.
For the test configuration in Figure 13, a 33μF
electrolytic capacitor (ESR<0.1Ω at 100kHz), mounted
close to the power module helps ensure the stability of
the unit. Consult the factory for further application
guidelines.
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL 60950-1-3, CSA C22.2 No. 60950-00, and VDE
0805:2001-12 (IEC60950-1).
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75Vdc), for the module’s output to be considered as
meeting the requirements for safety extra-low voltage
(SELV), all of the following must be true:
Note: Do not ground either of the input pins of the
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
All flammable materials used in the manufacturing of
these modules are rated 94V-0, or tested to the
UL60950 A.2 for reduced thickness.
For input voltages exceeding –60 Vdc but less than or
equal to –75 Vdc, these converters have been
evaluated to the applicable requirements of BASIC
INSULATION between secondary DC MAINS
DISTRIBUTION input (classified as TNV-2 in Europe)
and unearthed SELV outputs (-B option only).
The input to these units is to be provided with a
maximum 5 A time-delay fuse in the ungrounded lead.
The input source is to be provided with reinforced
One V
The input pins of the module are not operator
Another SELV reliability test is conducted on the
whole system (combination of supply source and
subject module), as required by the safety
agencies, to verify that under a single fault,
hazardous voltages do not appear at the module’s
output.
insulation from any other hazardous voltages,
including the ac mains.
or both the input and output pins are to be kept
floating.
accessible.
module without grounding one of the output
pins. This may allow a non-SELV voltage to
appear between the output pins and ground.
KW0006-010 Series Power Modules:
IN
pin and one V
OUT
pin are to be grounded,
7