1393105-4 TE Connectivity, 1393105-4 Datasheet

Electromechanical Relay SPDT 10A 24VDC 472Ohm Socket

1393105-4

Manufacturer Part Number
1393105-4
Description
Electromechanical Relay SPDT 10A 24VDC 472Ohm Socket
Manufacturer
TE Connectivity
Type
Industrial Relayr
Datasheet

Specifications of 1393105-4

Contact Arrangement
SPDT
Dc Coil Voltage
24 V
Coil Current
50.84 mA
Mounting
Socket
Relay Construction
Non-Latching
Coil Voltage Dc
24V
Contact Form
1 Form C
Coil Resistance
472Ohm
Contact Current Rating
10A
Contact Material
Silver Cadmium Oxide
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
34.9mm
Product Depth (mm)
37.3mm
Product Length (mm)
48.8mm
Pin Count
8
Mounting Style
Socket
Termination Style
8-Pin Circular Plug
Lead Free Status / Rohs Status
Compliant
Features
• Industry standard octal-type termination for quick installation.
• Contact arrangements from 1 Form C (SPDT) to 3 Form C (3PDT).
• Indicator lamp and push-to-test options available on certain models.
• The KRPA is the automated manufactured version of the KRP .
Contact Data @ 25°C
Arrangements: See Ordering Information Table.
Materials: Silver or silver-cadmium oxide, with or without gold flashing.
Expected Life: 10 million operations min., mechanical; 100,000
KA, KRP , KRPA
KRP , KRPA
KA UL Contact Ratings
Initial Dielectric Strength
Between Open Contacts: 500V rms.
Between All Elements: 1,500V rms.
Dimensions are shown for
reference purposes only.
Note: See KRPA, KRP , KA Ordering Information table.
1
2
Contact Code
Contact Code
Contact Code
Listed by C.S.A. for 5A @ 120VAC 80% PF
Listed by C.S.A. for 10A @ 120VAC 80% PF
Y
(Silver)
G&N
(Silver-Cad.
Oxide)
G&N
KRPA
G
Y
Y
operations min. @ rated loads.
Arrangement
Series
Factory Ratings
KA
KA
1, 2, 3 Poles
1, 2, 3 Poles
1
2
UL/CSA Contact Ratings @ 25°C
Arrangement
1, 2, 3 Poles
1, 2, 3 Poles
KRP
5A @ 120VAC, 3A @ 240VAC,
1/10 HP @ 120VAC, 1/6 HP @ 240VAC
10A @ 120VAC, 6A @ 240VAC
1/6 HP @ 120VAC, 1/3 HP @ 240VAC
10A @ 28VDC, 120VAC, 80% PF
6A @ 250VAC
5A @ 28VDC, 120VAC, 80% PF
Contact Ratings
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Contact Rating
5A @ 120VAC
3A @ 240VAC
1/10HP @ 120VAC
1/6HP @ 240VAC
10A @ 240VAC
1/2 HP @ 240VAC
1/3HP @ 120VAC
Contact Rating
KA
PDF Revised 9-03
Catalog 1308242
Specifications and availability
subject to change.
KRPA, KRP , KA, KR
5 to 10 Amp
General Purpose Relay
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Operate Data @ 25°C
Must-Operate Voltage:
Operate Time (Excluding Bounce):
Release Time (Excluding Bounce):
Environmental Data
Temperature Range:
Mechanical Data
Termination: Open Models: Solder terminals.
Weight: KA: 1.7 oz. (48.2g) approximately.
Coil Data @ 25°C
Duty Cycle: Continuous.
Initial Insulation Resistance: KRP , KRPA - 1000 Megohms, min.
Coil Data @ 25°C
KRP
KRPA
KA
Open Models: AC: -45°C to +70°C.
Enclosed Models: AC: -45°C to +55°C.
DC
Coils
AC
Coils
DC: 75% or less of nominal voltage.
AC: 85% or less of nominal voltage.
15 milliseconds typical @ nominal voltage.
10 milliseconds typical @ nominal voltage.
File E29244, E22575
File LR15734
KRPA, KRP: 3.0 oz. (85g) approximately.
Nominal
Voltage
AC
DC
AC
DC
Enclosed Models: Octal-type plug.
220
120
240
110
24
48
24
12
12
6
6
Enclosure: Transparent polycarbonate.
DC: -45°C to +85°C.
125mW per movable arm
DC: -45°C to +70°C.
Nominal Power
DC Resistance ( )
Use 110V relay with 10,000
1.2W
2VA
2VA
KA - 100 Megohms, min.
10,000
±10%
2,250
1,800
9,110
120
472
32
24
85
6
Maximum Power
Enclosed Models - 4VA
Enclosed Models - 3W
Open Models - 4VA
Open Models - 4W
series
5W Resistor in series
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Nominal Coil
Current (mA)
188
335
100
168
51
26.6
84
11.5
17 .5
8.75
P&B
737

Related parts for 1393105-4

1393105-4 Summary of contents

Page 1

KRPA KRP Features • Industry standard octal-type termination for quick installation. • Contact arrangements from 1 Form C (SPDT Form C (3PDT). • Indicator lamp and push-to-test options available on certain models. • The KRPA is the automated ...

Page 2

Ordering Information 1. Series: KRPA (Newer version, enclosed) KRP (Older version, enclosed) KA (Open style) 2. Contact Arrangement Form C (SPDT Form C (DPDT) 3. Coil Input AC, 50/60 Hz ...

Page 3

... Catalog 1308242 PDF Revised 9-03 KRP-3-H 20 Amp Small Relays File E22575 Coil Data @ 25°C See chart on page 105. Nominal Power: DC Coils: 1.2W Initial Insulation Resistance: 1,000 megohms. Operate Data @ 25°C Must-Operate Voltage: DC: 75% of nominal voltage. ...

Page 4

Outline Dimensions KA Series 1.06 MAX. .44 1 STUD (26.9) .25 (11.2) #6-32 (6.4) 1.92 MAX. THREAD (48.8) Tolerances on .XX Decimals ± .02 (± .5) Unless Otherwise Specified Tolerances on .XXX Decimals ± .005 (± .13) Unless Otherwise Specified ...

Page 5

... Sockets For KRP , KRPA Series Relays The following sockets are normally maintained in stock for immediate delivery. Screw Terminal, DIN Rail Snap-Mount Sockets (Use with mounting track 24A110) 27E891 10A, 300VAC 1.295 (32.89) 1.005 (25.53) 2.010 (51.05) .165 (4.19) DIA.TYP . .312 TYP . ...