5-1393252-7 TE Connectivity, 5-1393252-7 Datasheet - Page 3

W67-X2Q12-2=M6/M7/M9/W6/W7

5-1393252-7

Manufacturer Part Number
5-1393252-7
Description
W67-X2Q12-2=M6/M7/M9/W6/W7
Manufacturer
TE Connectivity
Datasheet

Specifications of 5-1393252-7

Current Rating
2A
Mounting Style
Din-Rail
Termination Style
Quick Connect
Operating Temp Range
-40C to 85C
Screening Level
Industrial
Number Of Poles
1
Lead Free Status / RoHS Status
Compliant
Ordering Information
Authorized distributors are more likely to stock the following items.
Ordering Information
Authorized distributors are more likely to stock the following items.
W6 Series
1. Circuit Breaker Mounting:
2. Number of Poles:
3. Circuit Function: (Only X is VDE approved)
4. Actuator: (One actuator per pole)
5. Termination:
6. Maximum Line Voltage: (See Table 1 for current ranges)
7. Time Delay Curve:
8. Amp Rating:
9. VDE Approval:
W9 Series
1. Circuit Breaker Mounting:
2. Number of Poles:
3. Circuit Function: (Only X is VDE approved)
4. Actuator: (One actuator per pole):
5. Maximum Line Voltage: (See Table 1 for current ranges)
6. Time Delay Curve:
7. Amp Rating:
8. VDE Approval:
W91-X112-1
W91-X112-2
W91-X112-3
W91-X112-5
W91-X112-7
W91-X112-10
W67-A2Q12-5
W67-A2Q12-10
W67-X2Q10-3
W67-X2Q10-5
W67-X2Q12-2
W67-X2Q12-3
Dimensions are shown for
reference purposes only.
W = #6-32 mounting threads.
67 = Single pole
A = Series trip with auxiliary switch (.093” QC)
1 = Black toggle
2 = White toggle
Q = .250” QC (DIN 46 244) [25A Max. VDE]
Note: “T” termination must be used for all ratings of 31 amps or above.
UL/CSA
TYPES
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
0.20
0.25
Blank = UL/CSA approved breaker
W = #6-32 mounting threads.
91 = Single pole
A = Series trip with auxiliary switch (.093” QC)
1 = Black toggle
UL/CSA
TYPES
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
0.20
0.25
0.50
Blank = UL/CSA approved breaker
0.50
0.75
1 = 277VAC, 50/60 Hz.
2 = 277/480VAC §
5 = 65VDC
7 = AC/DC 277VAC or 65VDC
§ Note: Maximum line voltage code “2, ” 277/480VAC, is UL, but not CSA.
1 = 277VAC, 50/60 Hz.
2 = 277/480VAC §
5 = 65VDC
7 = AC/DC 277VAC or 65VDC
§ Note: Maximum line voltage code “2, ” 277/480VAC, is UL, but not CSA.
0.75
1.0
1.5
(Delay curve 34 must be specified.)
(Delay curve 34 must be specified.)
W91-X112-15
W91-X112-20
W91-X112-40
W91-X112-50
W91-X113-5
W91-X113-10
W67-X2Q12-5
W67-X2Q12-7
W67-X2Q12-10
W67-X2Q12-15
W67-X2Q12-20
W67-X2Q12-30
1.0
1.5
3 = Black rocker
4 = White rocker
92 = Two pole
2.0
2.5
3.0
68 = Two pole
2.0
2.5
2 = White toggle
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
M = M3.0 x 0.5 mounting threads.
3.0
3.5
M = M3.0 x 0.5 mounting threads.
3.5
4.0
5.0
W91-X113-15
W91-X150-5
W91-X152-10
W91-X152-15
W91-X152-20
W91-X152-30
5 = Red rocker
6 = Grey rocker
W67-X2Q13-1
W67-X2Q13-2
W67-X2Q13-3
W67-X2Q13-10
W67-X2Q13-15
W67-X2Q13-20
Dimensions are in inches over
(millimeters) unless otherwise
specified.
V = VDE approved breaker without auxiliary switch
93 = Three pole
V = VDE approved breaker without auxiliary switch
4.0
5.0
VDE
TYPES
6.0
7 .0
7 .5
VDE
TYPES
69 = Three pole
X = Series trip
S = #8-32 screw [30A Max. VDE]
X = Series trip
6.0
7 .0
1 = 250VAC, 415/240VAC
5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
1 = 250VAC, 415/240VAC
5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
W91-X152-40
W91-X152-50
W91-X1110-20
W92-X112-1
W92-X112-2
W92-X112-3
Typical Part No.
W67-X2Q13-25
W67-X2Q13-30
W67-X2Q50-5
W67-X2Q50-10
W67-X2Q52-5
W67-X2Q52-10
9 = Red toggle
(Delay curve 34 must be specified.)
10.0
8.0
9.0
(Delay curve 34 must be specified.
7 .5
8.0
Issued 3-03 (PDF Rev. 11-06)
Typical Part No.
94 = Four pole
Catalog 1308242
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle
11.0
12.0
15.0
9.0
10.0
70 = Four pole
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by
adding "P" after curve, See delay curve section for availability and details
by adding "P" after curve. See delay curve section for availability and details.
W92-X112-5
W92-X112-7
W92-X112-10
W92-X112-15
W92-X112-20
W92-X112-25
W67-X2Q52-15
W67-X2Q52-20
W67-X2Q52-30
W67-X2Q110-15
W67-X2Q110-20
W68-X2Q12-3
B B
Specifications and availability
subject to change.
11.0
12.0
20.0
25.0
30.0
W 67- X
T = #10-32 screw [50A Max. VDE]
B B
15.0
20.0
)
W
35.0
40.0
45.0
W92-X112-30
W92-X112-40
W92-X112-50
W92-X113-15
W92-X113-20
W92-X1110-20
W68-X2Q12-5
W68-X2Q12-7
W68-X2Q12-10
W68-X2Q12-15
W68-X2Q12-20
W68-X2Q12-25
25.0
30.0
91- X
50.0
Consult factory for other values
35.0
40.0
2
Q
45.0
50.0
1
W92-X1110-30
W93-X112-5
W93-X112-10
W93-X112-15
W93-X112-20
W93-X112-25
W68-X2Q12-30
W68-X2Q13-15
W68-X2Q110-10
W68-X2Q110-20
W69-X2Q12-5
W69-X2Q12-10
1
Consult factory for
other values.
1
.
2-
2 2 - - 20
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
W93-X112-30
W93-X112-40
W93-X112-50
W93-X1110-20
W93-X1110-30
W69-X2Q12-15
W69-X2Q12-20
W69-X2Q12-25
W69-X2Q12-30
W69-X2Q110-20
W69-X2Q110-30
20
P&B
121

Related parts for 5-1393252-7