1986164-2 TE Connectivity, 1986164-2 Datasheet - Page 28

Solar Cable 1Conductors 10AWG 152.4m 5.33mm Tinned Copper Black 2600VDC/3000VAC Reel

1986164-2

Manufacturer Part Number
1986164-2
Description
Solar Cable 1Conductors 10AWG 152.4m 5.33mm Tinned Copper Black 2600VDC/3000VAC Reel
Manufacturer
TE Connectivity
Type
Solar Cabler
Datasheets

Specifications of 1986164-2

Number Of Conductors
1
Size
10 AWG
Conductor Material
Tinned Copper
Reel Length (imperial)
500ft
Reel Length (metric)
152.4m
Conductor Size Awg
10
Conductor Area Csa
5.26mm
Jacket Color
Black
External Diameter
5.461mm
Rohs Compliant
Yes
Color, Jacket
Black
Conductor Size
10 AWG
Insulation Material
Electron beam cross-linked Polyolefin
Material, Conductor
Stranded tin-plated copper
Standards
UL File E214122 and E314125, USE-2, RHH, RHW-2, XHH, XHHW-2 and Approved, VW-1 Flammability
Temperature, Operating
–40°C to +120°C
Voltage, Rating
1800/2600 VAC/VDC
Color
Black
Max Conductor Temperature
90° Wet or Dry
Voltage Rating
600 Volts (UL)
Product Type
Cable
Cable Type
RHH, RHW-2, XHHW and USE-2 Rated, UL 854 Approved
Wire Size (mm² [awg])
5.3² [10]
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Quantity
500 Ft. per Reel
Lead Free Status / Rohs Status
RoHS Compliant part
26
IMPORTANT NOTE
te.com/solar
Catalog 3-1773458-6 | Issue Date 04/2011
Termination of the Cable
Wires and Crimping of
General Comments
of the Connectors
the Contacts
3.1 Handling
Dimensions are in inches and millimeters unless otherwise specified.
Values in brackets are standard equivalents. Dimensions are shown
for reference purposes only. Specifications subject to change.
SOLARLOK Connectivity Systems for PV Installers
Assembly and Installation Guidelines
SOLARLOK plug connectors
ATTENTION : This connector is to be used only to interconnect firmly fixed cables
DO NOT DISCONNECT UNDER LOAD : Current path should only be disconnected
using approved disconnect devices.
SOLARLOK component cable can be labeled with label PN : 1718077-1.
(DO NOT DISCONNECT UNDER LOAD)
PROTECT AGAINST SHOCK : Ensure that conductors and their associated
connectors are separated from opposite polarity components.
Mounting and installation must be done by qualified and trained staff considering
all applying safety regulations. Failure to follow all instructions in Application
Specification 114-18488 (available at www.tycoelectronics.com/documents), including
using only approved TE tooling (if applicable), can result in improper installation
and/or crimping which is dangerous and may cause or contribute to electrical fires.
Should be used only by individuals with proper training and experience.
Any kind of pollution (dust, oil, humidity, etc.) during the assembly process or to the unmated
connector can degrade contact and connector performance. This applies in particular to the
seals and the crimping of the contacts. A clean assembly environment is essential.
When assembling the connectors, the following sequence must be followed:
1 : Stripping the wire to 9 +/- 1mm without damaging the strands
(please refer to application specification #114-74013)
SOLARLOK connectors use different crimp contacts for various wire gauges.
Possible wire gauges are 2.5 mm
The tools to be used are selected based upon the wire gauge.
For the application specification, please refer to specification #114-18488.
2
, 4.0 mm
USA: 1-800-522-6752
Canada: +1-905-475-6222
Mexico: +52 (0) 55-1106-0800
2
, and 6.0 mm
Latin/S. America: +54 (0) 11-4733-2200
Germany: +49 (0) 6251-133-1999
UK: +44 (0) 800-267666
2
, AWG 14, AWG 12 and AWG 10.
France: +33 (0) 1-3420-8686
Netherlands: +31 (0) 73-6246-999
China: +86 (0) 400-820-6015
Fig.1