BTA06-400CRG STMicroelectronics, BTA06-400CRG Datasheet

TRIAC STD 400V 6A 25MA TO-220AB

BTA06-400CRG

Manufacturer Part Number
BTA06-400CRG
Description
TRIAC STD 400V 6A 25MA TO-220AB
Manufacturer
STMicroelectronics
Datasheet

Specifications of BTA06-400CRG

Triac Type
Standard
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
25mA
Voltage - Off State
400V
Current - Gate Trigger (igt) (max)
25mA
Current - Non Rep. Surge 50, 60hz (itsm)
60A, 63A
Current - On State (it (rms)) (max)
6A
Voltage - Gate Trigger (vgt) (max)
1.3V
Package / Case
TO-220-3
Current - On State (it (rms) (max)
6A
Rated Repetitive Off-state Voltage Vdrm
400 V
Off-state Leakage Current @ Vdrm Idrm
5 uA
Gate Trigger Voltage (vgt)
1.5 V
Gate Trigger Current (igt)
50 mA
Holding Current (ih Max)
25 mA
Forward Voltage Drop
1.55 V
Mounting Style
Through Hole
Repetitive Peak Forward Blocking Voltage
400 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-3383-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTA06-400CRG
Manufacturer:
ST
0
SNUBBERLESS™, LOGIC LEVEL & STANDARD
Table 1: Main Features
DESCRIPTION
Available either in through-hole or surface-mount
packages, the BTA06 and BTB06 triac series is
suitable for general purpose AC switching. They
can be used as an ON/OFF function in applica-
tions such as static relays, heating regulation, in-
duction motor starting circuits... or for phase
control operation in light dimmers, motor speed
controllers,...
The snubberless and logic level versions (BTA/
BTB...W) are specially recommended for use on
inductive loads, thanks to their high commutation
performances.
By using an internal ceramic pad, the BTA series
provides
2500V
E81734).
Table 3: Absolute Maximum Ratings
February 2006
Symbol
I
P
V
T(RMS)
I
dI/dt
T
I
G(AV)
TSM
DRM
GM
Symbol
I
T
I
stg
I
²
RMS
T(RMS)
GT (Q
t
j
/V
) complying with UL standards (File ref.:
®
RRM
voltage
1
)
RMS on-state current (full sine
wave)
Non repetitive surge peak on-state
current (full cycle, T
I
Critical rate of rise of on-state cur-
rent I
Peak gate current
Average gate power dissipation
Storage junction temperature range
Operating junction temperature range
²
t Value for fusing
G
= 2 x I
insulated
600 and 800
5 to 50
Value
GT
6
, t
r
tab
≤ 100 ns
j
initial = 25°C)
(rated
Parameter
Unit
mA
A
V
at
BTA06 and BTB06 Series
TO-220AB
TO-220AB Ins. T
F = 50 Hz
F = 60 Hz
t
F = 120 Hz
t
p
p
REV. 6
= 10 ms
= 20 µs
Table 2: Order Codes
TO-220AB Insulated
BTA06-xxxxxRG
BTB06-xxxxxRG
A1
A2
Part Number
G
(BTA06)
T
t = 20 ms
t = 16.7 ms
T
T
T
c
c
j
j
j
= 125°C
= 125°C
= 125°C
= 110°C
= 105°C
G
A2
A1
- 40 to + 150
- 40 to + 125
See page table 8 on
A1
A2
Value
6A TRIAC
TO-220AB
G
60
63
21
50
(BTB06)
6
4
1
Marking
page 6
Unit
A/µs
A2
A
°C
W
A
A
A
²
s
1/7
S

Related parts for BTA06-400CRG

BTA06-400CRG Summary of contents

Page 1

... DESCRIPTION Available either in through-hole or surface-mount packages, the BTA06 and BTB06 triac series is suitable for general purpose AC switching. They can be used as an ON/OFF function in applica- tions such as static relays, heating regulation, in- duction motor starting circuits... or for phase control operation in light dimmers, motor speed controllers, ...

Page 2

... BTA06 and BTB06 Series Tables 4: Electrical Characteristics (T ■ SNUBBERLESS and Logic Level (3 quadrants) Symbol Test Conditions I ( Ω 3.3 kΩ D DRM 125° ( 100 1 dV/dt (2) D DRM (dV/dt)c = 0.1 V/µs (dV/dt V/µs (dI/dt)c (2) Without snubber ■ Standard (4 quadrants) Symbol Test Conditions I (1) ...

Page 3

... I (A) T(RMS Figure 4: On-state characteristics (maximum values) I (A) TM 100 T max 0.85V 1E+1 1E+2 5E+2 0.5 BTA06 and BTB06 Series Value 1.8 2.7 60 BTA T (° 100 max Ω V (V) TM 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Unit °C/W °C/W BTB 125 4.5 5 ...

Page 4

... BTA06 and BTB06 Series Figure 5: Surge peak on-state current versus number of cycles I (A) TSM Non repetitive T initial=25° Repetitive T =105° Number of cycles Figure 7: Relative variation of gate trigger current, holding current and latching current versus junction temperature (typical values =25° 2.5 2 ...

Page 5

... BTA/BTB06-xxxTW BTB: non insulated TO-220AB package 600 BW (RG 50mA Snubberless CW = 35mA Snubberless TW = 5mA Logic Level Voltage (xxx) Sensitivity 600 V 800 BTA06 and BTB06 Series Type Package Standard TO-220AB Snubberless TO-220AB Standard TO-220AB Snubberless TO-220AB Logic level TO-220AB Logic Level TO-220AB 5/7 ...

Page 6

... BTA06 and BTB06 Series Figure 12: TO-220AB (insulated and non insulated) Package Mechanical Data B Ø order to meet environmental requirements, ST offers these devices in ECOPACK® packages. These packages have a Lead-free second level interconnect . The category of second level interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label ...

Page 7

... Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan - Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America All other names are the property of their respective owners © 2006 STMicroelectronics - All rights reserved STMicroelectronics group of companies www.st.com BTA06 and BTB06 Series 7/7 ...

Related keywords