Q8006VH3 Littelfuse / Teccor Brand Thyristors, Q8006VH3 Datasheet

ALTERNISTOR 800V 6A TO-251-VPAK

Q8006VH3

Manufacturer Part Number
Q8006VH3
Description
ALTERNISTOR 800V 6A TO-251-VPAK
Manufacturer
Littelfuse / Teccor Brand Thyristors
Datasheet

Specifications of Q8006VH3

Triac Type
Alternistor - Snubberless
Mounting Type
Through Hole
Configuration
Single
Current - Hold (ih) (max)
15mA
Voltage - Off State
800V
Current - Gate Trigger (igt) (max)
10mA
Current - Non Rep. Surge 50, 60hz (itsm)
80A, 85A
Current - On State (it (rms)) (max)
6A
Voltage - Gate Trigger (vgt) (max)
1.3V
Package / Case
TO-251-3 Long Leads, IPak, TO-251AB
Current - On State (it (rms) (max)
6A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications are subject to change without notice.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Please refer to http://www.littelfuse.com for current information.
Note: xx = voltage, y = sensitivity
©2008 Littelfuse, Inc.
Symbol
I
I
I
di/dt
I
P
T
T
Agency Approval
Main Features
Schematic Symbol
Absolute Maximum Ratings — Sensitive Triac
T(RMS)
TSM
2
GTM
I
V
I
J
stg
T(RMS)
GT (Q1)
t
G(AV)
Symbol
DRM
Agency
®
/V
RRM
Lxx06xx & Qxx06xx & Qxx06xHx Series
MT2
Non repetitive surge peak on-state current
Operating junction temperature range
RMS on-state current (full sine wave)
Critical rate of rise of on-state current
Average gate power dissipation
I
G
Storage temperature range
= 50mA with 0.1μs rise time
(full cycle, T
Peak gate trigger current
400 to 1000
I
2
t Value for fusing
5 to 50
Value
Agency File Number
L Package: E71639
6
J
initial = 25°C)
G
Teccor
6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
MT1
Unit
mA
A
V
(4 Quadrants)
Parameter
®
brand Thyristors
Lxx06Vy / Lxx06Dy/ Lxx06Ry
Revised: July 9, 2008
61
f = 120 Hz
f = 50 Hz
f = 60 Hz
t
Lxx06Ly
p
Description
6 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Sensitive type devices guarantee gate control in
Quadrants I & IV needed for digital control circuitry.
Standard type devices normally operate in Quadrants I &
III triggered from AC line.
Alternistor type devices only operate in quadrants I, II, &
III and are used in circuits requiring high dv/dt capability.
Features & Benefits
Applications
Excellent for AC switching and phase control applications
such as heating, lighting, and motor speed controls.
Typical applications are AC solid-state switches, light
dimmers, power tools, home/brown goods and white
goods appliances.
Alternistor Triacs (no snubber required) are used in
applications with extremely inductive loads requiring
highest commutation performance.
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
to 1000 V
junctions
to 85 A
“L - Package” is UL
recognized for 2500Vrms
eliminates arcing or
10 μs
t
p
= 8.3 ms
t = 16.7 ms
T
T
T
T
T
t = 20 ms
J
J
J
C
C
= 110°C
= 110°C
= 110°C
= 80°C
= 85°C
Lxx06xx & Qxx06xx & Qxx06xHx Series
contact bounce that
create voltage transients
from reaction of switching
events
generation, depending on
activation point of
sine wave
activation pulse in each
half-cycle
-40 to 150
-40 to 110
Value
0.4
1.6
50
60
15
70
6
Unit
A/μs
A
W
°C
°C
A
A
A
®
2
s

Related parts for Q8006VH3

Q8006VH3 Summary of contents

Page 1

... Please refer to http://www.littelfuse.com for current information. Teccor brand Thyristors ® 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Description 6 Amp bi-directional solid state switch series is designed for AC switching and phase control applications such as motor speed and temperature modulation controls, lighting controls, and static switching relays ...

Page 2

... Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Absolute Maximum Ratings — Standard Triac Symbol I RMS on-state current (full sine wave) T(RMS) Non repetitive surge peak on-state current I (full cycle, T initial = 25°C) TSM Value for fusing Critical rate of rise of on-state current ...

Page 3

... Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Please refer to http://www.littelfuse.com for current information. Teccor brand Thyristors ® 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs — Sensitive Triac (4 Quadrants) Quadrant Lxx06x5 I – II – III MAX ...

Page 4

... Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Static Characteristics Symbol 11. Lxx06xy Qxx06xy DRM RRM DRM RRM Qxx06xHy Thermal Resistances Symbol Junction to case (AC) R (J-C) R Junction to ambient (J-A) Note voltage package sensitivity type & sensitivity Figure 1: Definition of Quadrants ALL POLARITIES ARE REFERENCED TO MT1 ...

Page 5

... Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Please refer to http://www.littelfuse.com for current information. Teccor brand Thyristors ® 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Figure 4: Normalized DC Gate Trigger Voltage for All Quadrants vs. Junction Temperature 4.0 3.0 2.0 1 ...

Page 6

... Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Figure 9: Maximum Allowable Ambient Temperature vs. On-State Current (Sensitive / Standard Triac) 120 100 Lxx06Ly Lxx06Ry 80 L/Qxx06Vy 60 CURRENT WAVEFORM: Sinusoidal 40 LOAD: Resistive or Inductive CONDUCTION ANGLE: 360° FREE AIR RATING – NO HEATSINK 20 0.0 0.2 0.4 ...

Page 7

... Specifications are subject to change without notice. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Please refer to http://www.littelfuse.com for current information. Teccor brand Thyristors ® 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Qxx06Ly Qxx06Ry 100 1000 100 1000 ...

Page 8

... Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Soldering Parameters Reflow Condition - Temperature Min (T ) s(min) Pre Heat - Temperature Max (T ) s(max) - Time (min to max Average ramp up rate (Liquidus Temp peak Ramp-up Rate S(max Temperature (T ) (Liquidus) L Reflow - Temperature ( Peak Temperature ( Time within 5°C of actual peak ...

Page 9

... Specifications are subject to change without notice. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Please refer to http://www.littelfuse.com for current information. Teccor brand Thyristors ® 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs AREA (REF.) 0. Dimension 8.13 Min .320 A 0 ...

Page 10

... Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Dimensions — TO-263AB (N-Package) — MEASURING POINT MT2 GATE MT1 11.68 2.16 .460 .085 7.01 7.01 .276 .276 16.89 .665 8.89 1.40 .350 .055 3.81 .150 2.03 .080 6.60 .260 Dimensions — TO-251AA (V-Package) — V-PAK Through Hole ...

Page 11

... Specifications are subject to change without notice. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Please refer to http://www.littelfuse.com for current information. Teccor brand Thyristors ® 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs 5.34 .210 2 Dimension Min A ...

Page 12

... Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Product Selector Voltage Part Number 400V 600V 800V Lxx06L5 X X Lxx06D5 X X Lxx06R5 X X Lxx06V5 X X Lxx06L6 X X Lxx06D6 X X Lxx06R6 X X Lxx06V6 X X Lxx06L8 X X Lxx06D8 X X Lxx06R8 X X Lxx06V8 X X Qxx06VH3 ...

Page 13

... Specifications are subject to change without notice. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Please refer to http://www.littelfuse.com for current information. Teccor brand Thyristors ® 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs 0.157 (4.0) 0.059 DIA (1.5) Gate ...

Page 14

... Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Part Numbering System Lxx06xx & Qxx06xx & Qxx06xHx Series Teccor brand Thyristors ® Part Marking System ® 74 Revised: July 9, 2008 Please refer to http://www.littelfuse.com/series/triac.html for current information. TO-252AA – (D Package) TO-251AA – (V Package) © ...

Related keywords