W2E142-BB01-87 EBM-Papst Industries Inc, W2E142-BB01-87 Datasheet - Page 5

FAN TUBEAXIAL 172X38MM 230VAC

W2E142-BB01-87

Manufacturer Part Number
W2E142-BB01-87
Description
FAN TUBEAXIAL 172X38MM 230VAC
Manufacturer
EBM-Papst Industries Inc
Series
W2E142r
Type
Roundr
Datasheets

Specifications of W2E142-BB01-87

Voltage Rating
230VAC
Power (watts)
24W
Size / Dimension
Rectangular/Rounded- 172mm L x 150mm H x 38mm W
Termination
2 Terminals
Fan Type
Tubeaxial
Termination Style
57 dB(A)
Air Flow
230.0 CFM (6.51m³/min)
Bearing Type
Ball
Weight
2 lbs (907.2g)
Noise
57 dB(A)
Brand/series
W2E142
Dimensions
5.91 x 6.77 x 1.5 "
Direction
Exhaust over Struts
Noise Level
57 dBA
Power, Rating
28 W
Size
150 × 172 × 38 mm (5.91 × 6.77 × 1.5 Inch) In. (mm)
Voltage, Rating
230 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rpm
-
Static Pressure
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
W2E142BB0187
4. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REME-
Do not perform any repairs on your device. Return the fan to ebm-papst for repair
or exchange.
Malfunction/error Possible cause
Motor does not
turn
Impeller running
roughly
Overtemperature
of motor
DIES
WARNING
Terminals and connections have voltage even in a unit that is
shut off
Electric shock
➜ Wait five minutes after disconnecting the voltage at all poles
CAUTION
Electrical load on the capacitor after device is switched off
Electric shock, risk of injury
➜ Discharge the capacitor before working on the device.
(Applicable only to devices with capacitors)
CAUTION
The motor restarts automatically when operating voltage is
applied, e.g. after a power failure.
Danger of injury
Keep out of the danger zone of the device.
➜ When working on the device, switch off the mains supply voltage
➜ Wait until the device stops.
➜ If thermal overload protectors are led through, insert these into
If the device remains out of use for some time, e.g. when in storage,
we recommend switching the device on for at least 2 hours to allow
any condensate to evaporate and to move the bearings.
If you have any other problems, contact ebm-papst.
before touching the unit.
and secure the latter from being switched on again.
the control circuit so that the cooled off motor does not switch on
independently after a fault.
Mechanical blockage
– Mains supply voltage
– Faulty connection
– Motor winding broken
– Thermal overload pro-
– Imbalance in rotating
– Ambient temperature
– Unacceptable operat-
– Insufficient cooling
faulty
tector responded
(applicable only to
devices with off-board
TOPs)
parts
too high
ing point
Possible remedy
– Switch off, de-energise, and
– Check mains supply voltage,
– Correct the connection
– Replace the device
– Allow motor to cool off,
– Clean the device, if imbal-
– Lower ambient temperature
– Check operating point
– Improve cooling
remove mechanical block-
age
restore power supply
locate and rectify cause of
error, if necessary cancel
switch-on inhibitor
ance is still evident after
cleaning, replace device
if possible
4.1 Safety examination
What has to be tested?
Protective casing against
accidental contact
Fan for damage
Mounting of fan
Mounting of connecting cables
Insulation of the cables
How to test?
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Frequency
At least every 6 months
At least every 6 months
At least every 6 months
At least every 6 months
At least every 6 months
5/5