W2G110-AK43-31 EBM-Papst Industries Inc, W2G110-AK43-31 Datasheet - Page 7

FAN TUBEAXIAL 119X38MM 24VDC

W2G110-AK43-31

Manufacturer Part Number
W2G110-AK43-31
Description
FAN TUBEAXIAL 119X38MM 24VDC
Manufacturer
EBM-Papst Industries Inc
Series
W1G110r

Specifications of W2G110-AK43-31

Current Type
DC
Supply Voltage
24 V
Bearing Type
Ball
Termination Style
61 dB(A)
Fan Type
Tubeaxial
Size / Dimension
Square - 119mm L x 119mm H x 38mm W
Voltage - Rated
24VDC
Power (watts)
15.0W
Features
Locked Rotor Sensor
Rpm
4400 RPM
Noise
61 dB(A)
Air Flow
140.0 CFM (3.96m³/min)
Termination
2 Terminals
Weight
1.1 lbs (498.9g)
Voltage Range
16 ~ 28VDC
Airflow
140 CFM
Power Rating
1.5 W
External Height
119mm
External Width
119mm
External Depth
38mm
Flow Rate
156CFM
Noise Rating
54dBA
Power Connection Type
Lead Wires
Product
Fans
Brand/series
W2G110
Dimensions
150 x 55 mm
Power, Rating
11 W
Size
5.91 x 2.17 (150 x 55) In. (mm)
Voltage, Rating
N24 VDC
Flow Rate - Imperial
156CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Static Pressure
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
381-2323
W2G110-AK43-31
W2G110AK4331
4.5 Checking the connections
4.6 Switch on device
Inspect the device for visible external damage and the proper function of
the protective features before switching it on.
4.7 Switching off the device
Item no.: 50872-5-9970 · Revision status: KM71618 · Print-out on 21/10/2010 · Created by A. Kehm (VM---) · Page 7 of 8
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W2G110-AK43-31
Make sure that the power is off (all phases).
Secure it from being switched on again.
Check that the mating connector is correctly locked into the panel
connector.
Check that the mating connector is correctly crimped to the
connection line.
Apply the nominal voltage to the voltage supply.
Start the device by changing the input signal.
Disconnect the device from the supply voltage.
WARNING
Hot motor housing
Fire hazard
Ensure that no combustible or flammable materials are
located close to the fan.
Operating instructions
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
Do not perform any repairs on your device. Return the device to ebm-
papst for repair or replacement.
Malfunction/error
Motor does not turn
Impeller running
roughly
Overtemperature of
electronics/motor
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor automatically restarts, e.g. after a power failure.
Danger of injury
If the device remains out of use for some time, e.g. when in
storage, we recommend switching the device on for at least 2
hours to allow any condensate to evaporate and to move the
bearings.
If you have any other problems, contact ebm-papst.
Wait for five minutes after disconnecting the voltage at all
poles before touching the unit.
Keep out of the danger zone of the device.
When working on the device, switch off the mains
supply voltage and secure the latter from being switched on
again.
Wait until the device stops.
Possible cause
Mechanical blockage
Mains supply voltage
faulty
Faulty connection
Imbalance in rotating
parts
Insufficient cooling
Ambient temperature
too high
Unacceptable
operating point
Possible remedy
Switch off, de-
energise, and remove
mechanical blockage
Check mains supply
voltage, restore power
supply
apply control signal
Correct connection,
see connection diagram
Clean the device, if
imbalance still evident
after cleaning, replace
device
Improve cooling if
possible.
Reset by switching
off the mains supply
voltage for at least 20
s after motor standstill
Lower ambient
temperature if possible.
Check operating point

Related parts for W2G110-AK43-31