IMPELLER MTRZD 175X62MM 48VDC

R1G175-AB41-02

Manufacturer Part Number
R1G175-AB41-02
Description
IMPELLER MTRZD 175X62MM 48VDC
Manufacturer
EBM-Papst Industries Inc
Series
R1G175r
Type
Impellersr

Specifications of R1G175-AB41-02

Current Type
DC
Supply Voltage
48 V
Bearing Type
Ball
Termination Style
65 dB(A)
Noise
65 dB(A)
Fan Type
Motorized Impellers
Size / Dimension
Round - 175mm Dia x 69mm W
Voltage - Rated
48VDC
Power (watts)
34.0W
Features
PWM Control; Speed Sensor (Tach)
Rpm
3100 RPM
Air Flow
330.0 CFM (9.34m³/min)
Termination
4 Wire Leads
Weight
1.6 lbs (725.7g)
Current Rating
0.800A
Voltage Range
36.0 ~ 57.0VDC
Operating Temperature
-13 ~ 140°F (-25 ~ 60°C)
Airflow
330 CFM
Frame Dimensions (mm)
175 mm x 62 mm
Power Rating
34 W
External Depth
69mm
External Diameter
175mm
Flow Rate
330CFM
Noise Rating
65dBA
Power Connection Type
Lead Wires
Brand/series
R1G175 Series
Diameter, Outer
175 mm
Dimensions
6.9"Dia.x2.72"W
Material, Impeller
Plastic
Noise Level
65 dBA
Power, Rating
34 W
Size
Φ 175 mm (6.89")
Special Features
Tachometer
Standards
UL Listed, CSA Certified, VDE Approval
Temperature, Ambient
60 °C (Max.)
Temperature, Operating, Maximum
+60 °C
Voltage, Rating
48 VDC
Diameter
175mm
Flow Rate - Imperial
330CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Static Pressure
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
381-1159
R1G175-AB41-02
R1G175AB4102
5.1 Cleaning
5.2 Safety test
Item no.: 50066-5-9970 · Revision status: KM70943 · Print-out on 27/08/2010 · Created by P. Praktikant (PR- ) · Page 9 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
What has to be
tested?
Protective casing
against accidental
contact
Device for damage
Mounting of device
Mounting of
connecting cables
Insulation of the cables Visual inspection
R1G175-AB41-02
If you have any other problems, contact ebm-papst.
NOTE
Damage to the device during cleaning.
Malfunction possible
Do not clean the device using a water jet or high-pressure
washer.
Do not use any cleaners containing acids,
bases or solvents.
How to test?
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Frequency
at least every 6 months
at least every 6 months
at least every 6 months
at least every 6 months
at least every 6 months
Operating instructions