W2G130-AA31-01 EBM-Papst Industries Inc, W2G130-AA31-01 Datasheet - Page 5

FAN TUBEAXIAL 150X55MM 12VDC

W2G130-AA31-01

Manufacturer Part Number
W2G130-AA31-01
Description
FAN TUBEAXIAL 150X55MM 12VDC
Manufacturer
EBM-Papst Industries Inc
Series
W2G130r
Type
DC Fanr
Datasheets

Specifications of W2G130-AA31-01

Bearing Type
Ball
Power (watts)
14.0W
Size / Dimension
Round - 150mm Dia x 55mm W
Termination
2 Wire Leads
Fan Type
Tubeaxial
Termination Style
51 dB(A)
Air Flow
203.0 CFM (5.75m³/min)
Voltage - Rated
12VDC
Weight
2.2 lbs (997.9g)
Voltage Range
6 ~ 16VDC
Noise
51 dB(A)
External Diameter
150mm
Current Type
DC
Supply Voltage
12VDC
Noise Rating
51dBA
Size
150 Dia. X 55 D Mm
Diameter
150mm
Power Rating
14W
Operating Input Voltage Range
6V to 16V
Bearings
Ball
Noise Level
51dB
Housing Material
Aluminum Die Cast
Product Length (mm)
150mm
Product Height (mm)
55mm
Product Depth (mm)
172mm
Voltage Rating
12V
Fan Rotation
Counter Clockwise
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Rpm
-
Static Pressure
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
W2G130AA3101
4. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REME-
Do not perform any repairs on your device. Return the fan to ebm-papst for repair
or exchange.
4.1 Safety examination
What has to be tested?
Protective casing against
accidental contact
Fan for damage
Mounting of fan
Mounting of connecting cables
Mounting of protective earth
connection
Insulation of the cables
Malfunction/error Possible cause
Motor does not
turn
Impeller running
roughly
Overtemperature
of electronics
Overtemperature
of motor
Incorrect rotor
position detection
DIES
WARNING
Terminals and connections have voltage even in a unit that is
shut off
Electric shock
➜ Wait five minutes after disconnecting the voltage at all poles
CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor automatically restarts, e.g. after a power failure.
Danger of injury
Keep out of the danger zone of the device.
➜ When working on the device, switch off the mains supply voltage
➜ Wait until the device stops.
If the device remains out of use for some time, e.g. when in storage,
we recommend switching the device on for at least 2 hours to allow
any condensate to evaporate and to move the bearings.
If you have any other problems, contact ebm-papst.
before touching the unit.
and secure the latter from being switched on again.
Mechanical blockage
– Mains supply voltage
– Imbalance in rotating
– Ambient temperature
– Insufficient cooling
– Unacceptable opera-
– Failure of electronics
faulty
parts
too high
ting point
(not applicable to DC-
fed devices)
How to test?
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Possible remedy
– Switch it off and remove
– Check mains supply voltage,
– Apply control signal
– Clean the device; if imbalan-
– Lower ambient temperature
– Reset by reducing control
mechanical blockage
restore power supply
ce still evident after clea-
ning, replace device
if possible.
input to 0.
Frequency
At least every 6 months
At least every 6 months
At least every 6 months
At least every 6 months
At least every 6 months
At least every 6 months
5/5