PFB0812UHE-T500 Delta Electronics, PFB0812UHE-T500 Datasheet

no-image

PFB0812UHE-T500

Manufacturer Part Number
PFB0812UHE-T500
Description
FAN DC AXIAL 12V IP55 80X38MM
Manufacturer
Delta Electronics
Series
PFBr
Datasheets

Specifications of PFB0812UHE-T500

Fan Type
Tubeaxial
Size / Dimension
Square - 80mm L x 80mm H x 38mm W
Voltage - Rated
12VDC
Power (watts)
18.6W
Features
IP55
Rpm
7500 RPM
Noise
61 dB(A)
Static Pressure
1.368 in H2O (340.8 Pa)
Air Flow
107.3 CFM (3.04m³/min)
Termination
2 Wire Leads
Bearing Type
Ball
Weight
0.441 lb (200.03g)
Current Rating
1.55A
Voltage Range
7.0 ~ 13.2VDC
Operating Temperature
14 ~ 140°F (-10 ~ 60°C)
Life Expectancy
50000 hrs @ 40°C
Termination Style
61 dB(A)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
603-1199
PFB0812UHE-T500
Customer
Description
Part No.
Delta Model No.
Sample Issue No.
Sample Issue Date.
DELTA ELECTRONICS (THAILAND) PUBLIC COMPANY LIMITED.
111 MOO 9 WELLGROW INDUSTRIAL ESTATE
BANGNA-TRAD ROAD, TAMBON BANGWUA,
AMPHUR BANGPAKONG, CHACHOENGSAO 24180 THAILAND
TEL. +66-(0)-38522455, FAX. +66-(0)-38522477
PLEASE SEND ONE COPY OF THIS SPECIFICATION
BACK AFTER YOU SIGNED APPROVAL FOR PRODUC-
TION PRE-ARRANGEMENT.
===============================================
SPECIFICATION FOR APPROVAL
APPROVED BY : _____________________________
DATE
DC FAN
PFB0812UHE-T500
Feb 03, 09
: _____________________________
Rev.
Rev.
00
DEL-0776A4

Related parts for PFB0812UHE-T500

PFB0812UHE-T500 Summary of contents

Page 1

... BACK AFTER YOU SIGNED APPROVAL FOR PRODUC- TION PRE-ARRANGEMENT. APPROVED BY : _____________________________ DATE DELTA ELECTRONICS (THAILAND) PUBLIC COMPANY LIMITED. 111 MOO 9 WELLGROW INDUSTRIAL ESTATE BANGNA-TRAD ROAD, TAMBON BANGWUA, AMPHUR BANGPAKONG, CHACHOENGSAO 24180 THAILAND TEL. +66-(0)-38522455, FAX. +66-(0)-38522477 DC FAN PFB0812UHE-T500 Feb 03 _____________________________ Rev. 00 Rev. DEL-0776A4 ...

Page 2

...

Page 3

...

Page 4

...

Page 5

...

Page 6

...

Page 7

Descriptions : 1. Delta will not guarantee the performance of the products if the application condition falls outside the parameters set forth in the specification written request should be submitted to Delta prior to approval if deviation from ...

Related keywords