A10463-01 Laird Technologies, A10463-01 Datasheet - Page 2

THERMAL INTERFACE PAD 12X18"

A10463-01

Manufacturer Part Number
A10463-01
Description
THERMAL INTERFACE PAD 12X18"
Manufacturer
Laird Technologies
Series
Tgon™ 810r
Type
Conductive Interface Padr
Datasheet

Specifications of A10463-01

Usage
Sheet
Shape
Rectangular
Outline
457.20mm x 304.80mm
Thickness
0.010" (0.254mm)
Color
Gray
Thermal Resistivity
0.10°C/W
Thermal Conductivity
240 W/m-K
Flammability Rating
UL 94 V-0
Length
305 mm
Operating Temperature Range
- 240 C to + 300 C
Tensile Strength
650 psi
Width
457 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Adhesive
-
Backing, Carrier
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
926-1010
Created on 11/9/2005 11:54:00 AM
Thermagon MSDS #052
A13814-00 Rev. B 10/14/04 EO #5082
Section 4: First Aid Measures
Ingestion:
Skin:
Inhalation:
Eyes:
Section 5: Fire Fighting Measures
Flammable Properties:
Extinguishing Media: Bulk material is non-combustible. Dusts are combustible – use water, carbon dioxide, dry
Special Firefighting Procedures: Material in or near fires should be cooled with a water spray or fog. A self
Section 6: Accidental Release Measures
Wipe or scrape spilled material and dispose of material in accordance with federal, state, and local regulations.
Section 7: Handling and Storage
Store in labeled, closed containers away from heat, spark, open flames and other sources of ignition. Do not let
containers of material accumulate in the workplace. Any dusts generated during handling or processing should be
cleaned up by damp mopping or vacuuming with a unit, which contains a HEPA filter. Dry sweeping can suspend
particulate matter in the atmosphere.
Flash Point: Unknown
Flammable Limits: LFL: Not Available
Sensitivity to Static Discharge: Not expected
Rinse mouth with water several times.
Wash with soap and water.
No evidence of adverse effects
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes and get
medical attention if irritation persists.
chemical or foam.
UFL: Not Available
contained breathing apparatus, operating in the positive pressure mode and full
fire fighting protective clothing should be worn for combating fires.
Page 2 of 4