MCZ33889BEG Freescale, MCZ33889BEG Datasheet - Page 34

no-image

MCZ33889BEG

Manufacturer Part Number
MCZ33889BEG
Description
Manufacturer
Freescale
Datasheet

Specifications of MCZ33889BEG

Number Of Transceivers
1
Standard Supported
CAN 2.0
Operating Supply Voltage (max)
18V
Operating Supply Voltage (min)
5.5V
Package Type
SOIC W
Supply Current
45mA
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
28
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCZ33889BEG
Manufacturer:
KOLIN
Quantity:
6 225
Part Number:
MCZ33889BEG
Manufacturer:
FREESCALE
Quantity:
20 000
condition is detected after 4 acknowledge bits are sent by the
MC33889B.
MC33889D:
by sampling the dominant pulse (recovery pulse) on S-H (S-
L), and incremented (up to 4) by sampling the recessive pulse
(detection pulses) on S-H (S-L). It is necessary to get 4
consecutive dominant samples (recovery pulse) to get to
zero. When reaching zero, the failure is recovered.
condition will not be detected by a single acknowledge bit
send by MC33889D, but requires a complete CAN message
(at least 4 dominant bits) send in dual wire mode, without
reception of any bit in single wire mode.
Tx permanent dominant detection:
permanent low state at the TX input which results in a
34
33889
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
In application, with CAN communication, a recovery
When detection is complete, the counter is decremented
In application with real CAN communication, a recovery
In addition to the previous list, the MC33889 detects a
permanent dominant bus state. If TX is low for more than
0.75-4ms, the bus output driver is disabled. This avoids
blocking communication between other nodes of the network.
TXD is reported via the SPI (RCR register bit D1:
TXFAILURE). Tx permanent dominant recovery is done with
TX recessive for more than typ 32us.
Rx pin behavior while CAN interface is in TermVbat.
the CAN interface is in TermVbat and the SBC in normal or
standby mode. When the bus is driven into a dominant state
by another sending node, each dominant state is reported at
Rx by a low level, after a delay of T
wake up comparator on CANL and CANH, and thus operates
also in case of bus failure. This is illustrated in the following
figure.
The MC33889D is able to signal bus activity on Rx while
The bus state report is done through the CAN interface
Analog Integrated Circuit Device Data
Freescale Semiconductor
WAKE
.