MPR083EJ Freescale, MPR083EJ Datasheet - Page 11

MPR083EJ

Manufacturer Part Number
MPR083EJ
Description
Manufacturer
Freescale
Datasheet

Specifications of MPR083EJ

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
1.8V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Package Type
TSSOP
Mounting
Surface Mount
Pin Count
16
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPR083EJ
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MPR083EJ
Manufacturer:
FRE/MOT
Quantity:
20 000
Part Number:
MPR083EJR2
Manufacturer:
ST
Quantity:
104
Sensors
Freescale Semiconductor
3.5
The Touch Acquisition Sample Period Register is used to determine the electrode scan period of the system. The I
address of the Touch Acquisition Sample Period Register is 0x06.
Table 5. Rotary Configuration Register Field Descriptions
Table 6. Touch Acquisition Sample Register Field Description
Touch Acquisition Sample Period Register
Reset:
RRBE
RTBE
TASP
Field
Field
RSE
ACE
RE
7:0
W
7
4
3
2
0
R
7
0
Figure 15. Touch Acquisition Sample Period Register
= Unimplemented
Rotary Sounder Enable – The Rotary Sounder Enable bit controls if data is sent to
the sounder.
0 Disable – Click Feedback Off
1 Enable – Click Feedback On
Auto Calibration Enable – The Auto Calibration Enable bit enables or disables the
auto calibration function.
0 Disable
1 Enable
Rotary Release Buffer Enable – The Rotary Release Buffer Enable bit determines
whether or not data is logged in the FIFO when the rotary transitions from a touched
to untouched state.
0 Disable – No Release Data Logged
1 Enable – Release Data Logged
Rotary Touch Buffer Enable – The Rotary Touch Buffer Enable bit determines
whether or not data is logged in the FIFO any time a button is pressed.
0 Disable – Touches are not logged
1 Enable – Touches are logged
Rotary Enable – The Rotary Enable bit enables or disables the touch sensor. When
disabled, no touches are detected.
0 Disable – Touches not detected
1 Enable – Touches detected
Touch Acquisition Sample Period – The Touch Acquisition Sample Period Field
selects or reports the multiplication factor that is used to determine how often
electrodes are scanned. The resulting factor must be in the range 1 to 32. If the
value is outside of this range the TASP will be set to 00011111.
00000000 Encoding 0 – Sets the TASP multiplication factor to 1
~
00011111 Encoding 31 – Sets the TASP multiplication factor to 32.
6
0
5
0
4
0
TASP
Description
Description
3
0
2
0
1
0
0
1
2
C slave
MPR083