SI2415-C-FTR Silicon Laboratories Inc, SI2415-C-FTR Datasheet - Page 27

no-image

SI2415-C-FTR

Manufacturer Part Number
SI2415-C-FTR
Description
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI2415-C-FTR

Main Category
Chipset
Data Rate
54.6875Kbps
Power Supply Type
Analog
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SI2415-C-FTR
Quantity:
2 409
+IFC Options
+IFC = A
+IFC = A,B
+ITF Options
+ITF = A
+ITF = A,B
+ITF = A,B,C
+MR = X
+MS Options
+MS = A
+MS = A,B
+MS = A,B,C
+MS = A,B,C,D
+MS = A,B,C,D,E
+MS = A,B,C,D,E,F
Command
Table 10. Basic AT Command Set (Command Defaults in Bold) (Continued)
Specifies the flow control to be implemented.
A
B
Transmit flow control threshold.
A
B
C
Modulation reporting control.
X
0
1
If enabled, the intermediate result code is transmitted at the point during connect negotiation.
The format of this result code is as follows:
+MCR: <carrier> e.g. +MCR: V32B
+MRR: <rate>
Modulation Selection.
A
B
C,D
E,F
Specifies the flow control method used by the modem to control data from the host
Specifies the flow control method used by the host to control data from the modem
0 None
1 Local XON/OFF flow control.
2 Hardware flow control (CTS).
Threshold above which the modem will generate a flow off signal
<0 to 511> bytes
Threshold below which the modem will generate a flow on signal
<0 to 511> bytes
Polling interval for <EM><BNUM> indicator
0 to 300 in 10 msec units.
2 Hardware flow control (RTS)
0 None
1 Local XON/OFF flow control. Does not pass XON/XOFF character to the remote
Disabled
Enabled
Mode
V21
V22
V22B
V32
V32B
V34
V90
modem.
0
1
Preferred modem carrier
Automatic modulation negotiation
Min TX rate/Max TX rate are optional numeric values that specify the lowest value
Min RX rate/Max RX rate are optional numeric values which specify the highest
at which the DCE may establish a connection. If unspecified (set to 0), they are
determined by the carrier and automode settings.
value at which the DCE may establish a connection. If unspecified (set to 0), they
are determined by the carrier and automode settings.
ITU-T V.21
ITU-T V.22
ITU-T V.32
ITU-T V.34 (default for Si2434)
ITU-T V.90 (default for Si2457)
ITU-T V.22bis (default for Si2404)
ITU-T V.32bis (default for Si2415)
Disabled
Enabled
e.g. +MRR: 14400
Rev. 1.1
Action
Si2457/34/15/04
27