E-STLC3075 STMicroelectronics, E-STLC3075 Datasheet - Page 13

no-image

E-STLC3075

Manufacturer Part Number
E-STLC3075
Description
Manufacturer
STMicroelectronics
Datasheet

Specifications of E-STLC3075

Number Of Channels
1
On-hook Transmission
Yes
Polarity Reversal
Yes
On-chip Ring Relay Driver
Yes
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Pin Count
44
Mounting
Surface Mount
Operating Current
55mA
Operating Supply Voltage (max)
12V
Lead Free Status / RoHS Status
Compliant
STLC3075
Metering pulse injection (TTX)
The metering pulses circuit consists of a burst shaping generator that generates a square
shaped wave and a low pass filter to reduce the harmonic distortion of the output signal.
The metering pulse is obtained from two logic signals:
These two signals are processed by a dedicated circuitry integrated on chip that generates
the metering pulse as an amplitude modulated shaped square wave (SQTTX) (see
Figure
Both the amplitude and the envelope of the square wave (SQTTX) can be programmed by
means of external components. In particular the amplitude is set by the two RLV resistors
while the shaping is set by the CS capacitor.
Figure 6.
The waveform so generated is then filtered and injected on the line.
The low pass filter is obtained by using the integrated buffer OP1 connected between pin
FTTX (OP1 non inverting input) and RTTX (OP1 output) (see
a “Sallen and Key” configuration. Depending on the external components count it is possible
to build an optimized application depending on the distortion level required. In particular
harmonic distortion levels equal to 13 %, 6 % and 3 % can be obtained respectively with
first, second and third order filters (see
The circuit showed in the “Application diagram” is related to the simple first order filter.
Once the shaped and filtered signal is obtained at RTTX buffer output it is injected on the
TIP/RING pins with a +6 dB gain or +12 dB gain.
It should be noted that this is the nominal condition obtained in presence of ideal TTX echo
cancellation (obtained via proper setting of RTTX and CTTX).
In addition the effective level obtained on the line will depend on the line impedance and the
protection resistors value. In typical applications (TTX line impedance =200 Ω, RP = 50 Ω,
CKTTX
D0
CKTTX: is a square wave at the TTX frequency (12 or 16KHz) that must be
permanently applied to the CKTTX pin or at least for all the duration of the TTX pulse
(including rising and decay phases).
D0: enables the TTX generation circuit and defines the TTX pulse duration.
Square wave pulse metering
GENERATOR
6).
SHAPING
BURST
Metering pulse generation circuit
CS
CTTX1
CTTX2
RLV
RLV
SQTTX
Low Pass Filter
Figure
CFL
R1
Required external components vs. filter order.
Order
6).
1
2
3
R2
FTTX
CFL
X
X
C2
C1
-
+
OP1
R1
Sinusoidal wave
pulse metering
X
X
Figure
C1
X
X
RTTX
Functional description
R2
6) and by implementing
X
X
C2
X
X
THD
13%
6%
3%
13/36