... High sensitivity with low nominal power consumption. • Single or double coil winding types available. Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G6H-2-DC6). ■ Non-latching Type Standard High-reliability Surface mount ■ ...
... Coil Data Standard and High Reliability Non-latching Type (G6H-2, G6H-2-100) Coil Rated voltage Rated current resistance (VDC) (mA) (Ω) 3 46.70 64.30 5 28.10 178 6 23.30 257 9 15.50 579 12 11.70 1,028 24 8.30 2,880 48 6.30 7,680 Surface Mount Non-latching Type (G6H-2-F) Coil Rated voltage ...
... Standard: -40° to 70° C (-40° to 158° F); Surface mount: -40° to 85° C (-40° to 185° F) 10% to 85% RH 100 million operations min. See “Characteristic Data” Approx. 1.5 g (0.05 oz) Electrical Service Life Ambient Temperature vs. Maximum Voltage (reference only) G6H Low Signal Relay 3 ...
... Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings). ■ High Temperature Usage Use the G6H-2-100 for high-temperature applications. [After testing at 70° C (158° F), (28 VDC, 100 mA resistive load, open and closed 1 million times), the contact resistance was 1 Ω maximum for the G6H-2 and 200 mΩ ...