H3DK-M1 AC/DC24-240 Omron, H3DK-M1 AC/DC24-240 Datasheet - Page 20

no-image

H3DK-M1 AC/DC24-240

Manufacturer Part Number
H3DK-M1 AC/DC24-240
Description
TIMER, MULTIFUNCTION, 5A, 24-240AC/DC
Manufacturer
Omron
Datasheet

Specifications of H3DK-M1 AC/DC24-240

Contact Configuration
SPDT
Delay Time Range
0.1s To 1200h
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Adjustment Type
Screwdriver Slot
Contact Current Ac Max
5A
Contact Current Dc
RoHS Compliant
Supply Voltage Range
24VAC To 240VAC / 24VDC To 240VDC
Time Range
0.1sec To 1200hr
Rohs Compliant
Yes
20
H3DK-G
Operating Procedures
■ Basic Operation
● Setting the Delta Time Range and the Star-delta Transfer
Star Time (t1) Range
■ Timing Chart
Note: “t1” is the start set time. “t2” is the transfer time.
Set the star-delta transfer time.
For ×1 (1 to 12 s), use side (A) (labeled “t1×1”).
For ×10 (10 to 120 s), use side (B) (labeled “t10×1”).
(See following diagram.)
Time (t2)
Star-delta transfer
time setting (t2)
Switches the start
time (t1) range.
Setting the Time Ranges
Delta contacts (25 and 26)
Star contacts (15 and 18)
Delta operation indicator
Star operation indicator
Power (A1 and A2)
0.5s
0.25s
0.1s
0.05s
(A)
t1x1
t2
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
t1x10
(B)
t2
t
t
0.5s
0.25s
0.1s
0.05s
1
2
: Star time setting
: Transfer time
t
1
t
2
● Setting the Time
The start time is set with the main dial.
0.5 s min.
Main dial
Setting the Time