TBF-2012-245-R1 Susumu, TBF-2012-245-R1 Datasheet - Page 5

FILTER BAND PASS BLUETOOTH 0805

TBF-2012-245-R1

Manufacturer Part Number
TBF-2012-245-R1
Description
FILTER BAND PASS BLUETOOTH 0805
Manufacturer
Susumu
Datasheet

Specifications of TBF-2012-245-R1

Center / Cutoff Frequency
2.45GHz
Filter Type
Bandpass
Impedance
50 Ohm
Attenuation Value
30dB @ 7.2GHz ~ 7.5GHz
Package / Case
0805 (2012 Metric)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage
-
Capacitance
-
Other names
408-1301-2
UNLESS OTHERWISE SPECIFIED
TOLERANCES ON ﹕
X
X.X
X.XX
ANGLES ± HOLE DIA. ±
TITLE :
Rapid change of temperature Satisfy Electrical Characteristics.
Humidity Resistance Test
Low Temperature Store
High Temperature Store
Load Life
= ±
= ±
= ±
7.3 Load Life
The Engineering Spec. for TBF-2012-245-R1 Band Pass Filter
ITEM
RELEASED BY ﹕Steven-Tseng
DESIGNED BY ﹕Steven-Tseng
CHECKED
APPROVED BY ﹕Wang-Kevin
SCALE ﹕ X
Without distinct damage.
Satisfy Electrical Characteristics.
Without distinct damage.
Satisfy Electrical Characteristics.
Without distinct damage.
Satisfy Electrical Characteristics.
Without distinct damage.
Satisfy Electrical Characteristics.
Without distinct damage.
Specification and Requirement
BY ﹕Steven-Tseng
UNIT ﹕ X
THIS DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF CYNTEC CO., LTD.
AND SHALL NOT BE REPRODUCED OR USED AS THE BASIS FOR THE
MANUFACTURE OR SALE OF APPARATUS OR DEVICES WITHOUT PERMISSION
DOCUMENT
乾坤科技股份有限公司
NO.
CYNTEC CO., LTD.
Apply 16 Volt voltage at 70±2℃
ambient
Perform 5 cycles as follows :
−55℃ for 30minutes → room
temperature for 3 minutes→
+125℃ for 30minutes → room
temperature for 3 minutes.
(Dwell time : 5 to 8 minutes)
Precondition at +25℃ for 1hour.
Let stand at temperature +40 ± 3
℃, 90~95% relative humidity for
1,000 hours before taking final
measurements.
Solder the sample on PCB.
Exposure at −55 ± 3℃ for 1,000
hours.
1~2 hours exposure at room
temperature and humidity, prior to
measurement.
Solder the sample on PCB.
Exposure at +85 ± 3℃ for 1,000
hours.
1~2 hours exposure at room
temperature and humidity, prior to
measurement.
Test Method
PAGE 5 OF 5
Preliminary
PAGE
REV.
A1