S25FL064A0LMFI001 Spansion Inc., S25FL064A0LMFI001 Datasheet - Page 17

S25FL064A0LMFI001

Manufacturer Part Number
S25FL064A0LMFI001
Description
Manufacturer
Spansion Inc.
Datasheet

Specifications of S25FL064A0LMFI001

Cell Type
NOR
Density
64Mb
Access Time (max)
9ns
Interface Type
Serial (SPI)
Boot Type
Not Required
Address Bus
1b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
SOIC W
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Synchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
8M
Supply Current
13mA
Mounting
Surface Mount
Pin Count
16
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S25FL064A0LMFI001
Manufacturer:
SPANSION
Quantity:
234
Part Number:
S25FL064A0LMFI001
Manufacturer:
SPANSION
Quantity:
20 000
Company:
Part Number:
S25FL064A0LMFI001
Quantity:
265
9.3
18
Read Identification (RDID)
The Read Identification (RDID) command outputs the one-byte manufacturer identification, followed by the
two-byte device identification, to the host system.
JEDEC assigns the manufacturer identification byte; for Spansion devices it is 01h. The device manufacturer
assigns the device identification: the first byte provides the memory type; the second byte indicates the
memory capacity. See
The host system must first select the device by driving CS# low. The RDID command is then written to SI,
and each bit is latched on the rising edge of SCK. The 24-bit device identification data is output from the
memory array on SO at a frequency f
The RDID command sequence is shown in
Driving CS# high after the device identification data has been read at least once terminates the READ_ID
command. Driving CS# high at any time during data output also terminates the RDID operation.
The device rejects any RDID command issued while it is executing a program, erase, or Write Status Register
operation, and continues the operation uninterrupted.
CS#
SCK
SO
SI
Mode 3
Mode 0
Hi-Z
Figure 9.3 Read Identification (RDID) Command Sequence and Data-Out Sequence
Manufacturer Identification
0
1
Table 9.1 on page 18
01h
Table 9.1 Read Identification (RDID) Data-Out Sequence
2
Command
3
4
5
SCK
6
S25FL064A
, on the falling edge of SCK.
7
Figure 9.3
D a t a
or
MSB
8
Table 9.4 on page 28
Manufacturer Identification
9
10 11 12
and
S h e e t
Memory Type
Table 9.4 on page
02h
13
14 15 16
for device ID data.
Device Identification
S25FL064A_00_C4 February 27, 2009
15
Device Identification
14
28.
17 18
13
Memory Capacity
3
28 29 30 31
2
16h
1
0

Related parts for S25FL064A0LMFI001