SLFDM44H-064JI STEC, SLFDM44H-064JI Datasheet - Page 6

no-image

SLFDM44H-064JI

Manufacturer Part Number
SLFDM44H-064JI
Description
Manufacturer
STEC
Type
Flash Diskr
Datasheet

Specifications of SLFDM44H-064JI

Density
64MByte
Operating Supply Voltage (typ)
3.3/5V
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Package Type
Not Required
Mounting
Surface Mount
Pin Count
44
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
3.18/4.75V
Operating Supply Voltage (max)
3.465/5.25V
Programmable
Yes
Lead Free Status / RoHS Status
Not Compliant
Signal Description
SimpleTech P/N:
(where p=connector; q=LP if low profile; r=plug-in and housing;
U=RoHS compliant lead-free; I=Ind. Op. Temp)
-DASP
D15-D00
-IOWR
-IORD
INTRQ
A2-A0
-CS1, -CS2
-CSEL
-IOIS16
-PDIAG
-DREQ
-DACK
-IORDY
-RESET
VCC
GND
NC
Signal Name
SLFDMpqr-064J(U)(I)
I / O
I / O
I / O
Dir
O
O
O
O
I
I
I
I
I
I
I
18, 16, 14, 12,
5, 7, 9, 11, 13,
26, 30, 40, 43
10, 8, 6, 4, 3,
2, 19, 22, 24,
35, 33, 36
15, 17
37, 38
41, 42
20, 44
Pin
39
23
25
31
28
32
34
21
29
27
1
This input/output is the Disk Active/Slave Present signal in the Master/
Slave handshake protocol.
All Task File operations occur in byte mode on the low order bus D00-D07
while all data transfers are 16 bit using D00-D15.
The I/O Write strobe pulse is used to clock I/O data on the drive Data
bus into the Drive controller registers when the Drive is configured to
use the I/O interface. The clocking will occur on the negative to
positive edge of the signal (trailing edge).
This is an I/O Read strobe generated by the host. This signal gates I/O
data onto the bus from the Drive.
Signal is the active high Interrupt Request to the host.
A[2:0] are used to select the one of eight registers in the Task File.
-CS1 is the chip select for the task file registers while -CS2 is used to select
the Alternate Status Register and the Device Control Register.
This internally pulled up signal is used to configure this device as a Master
or a Slave. When the pin is grounded, this device is configured as a Master.
When the pin is open, this device is configured as a Slave
Not used.
This input/output is the Pass Diagnostic signal in the Master/Slave
handshake protocol.
Not used.
Not used.
Not used, and pulled up to VCC through a 4.7K ohm resistor.
This input pin is the active low hardware reset from the host.
Power. Applies to the 44-pin version only.
Ground. (Pin 43 applies to 44-pin version only.)
No connect
Document Part Number 61000-02832-314 July 2005
Description
FLASH DISK MODULE
Page 6