FN2080-1-06 Schaffner EMC Inc, FN2080-1-06 Datasheet

FILTER MUTI-STAGE HI PERFORM 1A

FN2080-1-06

Manufacturer Part Number
FN2080-1-06
Description
FILTER MUTI-STAGE HI PERFORM 1A
Manufacturer
Schaffner EMC Inc
Series
FN 2080r
Datasheets

Specifications of FN2080-1-06

Filter Type
Power Line
Voltage - Rated
250V
Current
1A
Inductance
22mH
Mounting Type
Chassis Mount
Termination Style
Fast-On
Voltage Rating
250 VAC
Current Rating
1 A
Mounting Style
Chassis
Filtered
Yes
Frequency
DC to 400 Hz
Leakage Current
0.734 mA
Product
Power Line Filters
Type Of Inlet
Power Line
Capacitance
330nF
Inductance Min
22mH
Svhc
No SVHC (18-Jun-2010)
Termination Type
Tab
Approval Bodies
VDE, SEV
Capacitance X Type Capacitor
0.33µF
Rohs Compliant
Yes
Capacitance Y Type Capacitor
4.7nF
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
291-608
817-1317
FN2080 - 1 -06

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FN2080-1-06
Manufacturer:
SCHAFFNE
Quantity:
10
Technical specifications
Maximum continuous operating voltage:
Operating frequency:
Rated currents:
High potential test voltage:
Temperature range (operation and storage):
Flammability corresponding to:
Design corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
Features and benefits
n
n
n
Multi-stage high performance EMI filter
FN 2080 two-stage filters are designed for
easy and fast chassis mounting.
FN 2080 filters are also available as B
versions without Y-capacitors for medical
applications as well as A version with low
capacitance for safety critical applications
with necessity for low leakage currents.
All filters provide a high conducted
attenuation performance, based on chokes
with high saturation resistance and
excellent thermal behavior.
n
n
n
n
n
250VAC, 50/60Hz
dc to 400Hz
1 to 16A @ 40°C max.
P –> E 2000VAC for 2 sec
P –> E 2500VAC for 2 sec (B types)
P –> N 1100VDC for 2 sec
-25°C to +100°C (25/100/21)
UL 94V-2 or better
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
1,650,000 hours
1,700,000 hours (B types)
n
n
n
Rated currents from 1 to 16A
High differential and common-mode
attenuation
Good low frequency attenuation
Optional medical versions (B type)
Optional safety versions (A type)
FN 2080 two-stage filters are designed with
good low frequency attenuation.
FN 2080 filters are also available as single-
stage filters.
Various terminal options allow you to
select the desired connection style.
1-phase filters
FN 2080
Approvals
Typical electrical schematic
P
N
E
Typical applications
n
n
n
n
n
n
n
n
n
n
Line
Electrical and electronic equipment
Consumer goods
Household equipment
Building automation
Industrial applications
Machinery
Medical equipment
Electronic data processing equipment
Office automation and datacom equipment
Various noisy applications requiering good
filter performance
Cx
L
R
Cx
Cy
Cy
L1
Load
P‘
N‘

Related parts for FN2080-1-06

FN2080-1-06 Summary of contents

Page 1

... UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 1,650,000 hours 1,700,000 hours (B types) FN 2080 two-stage filters are designed with n good low frequency attenuation. FN 2080 filters are also available as single- n stage filters. Various terminal options allow you to n select the desired connection style. ...

Page 2

Components > FN 2080 Filter selection table Filter* Rated current Leakage current** @ 40°C (25°C) @ 230VAC/50Hz [A] FN 2080-1-.. 1 (1.2) FN 2080-3-.. 3 (3.5) FN 2080-6-.. 6 (6.9) FN 2080-10-.. 10 (11.5) FN 2080-12-.. 12 (13.8) FN ...

Page 3

Components > FN 2080 Mechanical data Connection style -06, 1 and 3A types Connection style -06, 16A types Connection style -07, ...

Page 4

Components > FN 2080 Dimensions 30.3 40.3 D 64.8 64.8 E 49.8 49 12.3 12.3 I 20.8 29.8 J 19.9 11.4 K 5.3 ...

Related keywords