GS88136BT-150 GSI TECHNOLOGY, GS88136BT-150 Datasheet - Page 28

no-image

GS88136BT-150

Manufacturer Part Number
GS88136BT-150
Description
Manufacturer
GSI TECHNOLOGY
Datasheet

Specifications of GS88136BT-150

Density
9Mb
Access Time (max)
7.5ns
Sync/async
Synchronous
Architecture
SDR
Clock Freq (max)
133.3MHz
Operating Supply Voltage (typ)
2.5/3.3V
Address Bus
18b
Package Type
TQFP
Operating Temp Range
0C to 70C
Number Of Ports
4
Supply Current
130mA
Operating Supply Voltage (min)
2.3/3V
Operating Supply Voltage (max)
2.7/3.6V
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
100
Word Size
36b
Number Of Words
256K
Lead Free Status / RoHS Status
Not Compliant
IDCODE
SAMPLE-Z
RFU
Rev: 1.06 6/2007
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
Typically, the Boundary Scan Register is loaded with the desired pattern of data with the SAMPLE/PRELOAD command.
Then the EXTEST command is used to output the Boundary Scan Register’s contents, in parallel, on the RAM’s data output
drivers on the falling edge of TCK when the controller is in the Update-IR state.
Alternately, the Boundary Scan Register may be loaded in parallel using the EXTEST command. When the EXTEST instruc-
tion is selected, the sate of all the RAM’s input and I/O pins, as well as the default values at Scan Register locations not asso-
ciated with a pin, are transferred in parallel into the Boundary Scan Register on the rising edge of TCK in the Capture-DR
state, the RAM’s output pins drive out the value of the Boundary Scan Register location with which each output pin is associ-
ated.
The IDCODE instruction causes the ID ROM to be loaded into the ID register when the controller is in Capture-DR mode and
places the ID register between the TDI and TDO pins in Shift-DR mode. The IDCODE instruction is the default instruction
loaded in at power up and any time the controller is placed in the Test-Logic-Reset state.
If the SAMPLE-Z instruction is loaded in the instruction register, all RAM outputs are forced to an inactive drive state (high-
Z) and the Boundary Scan Register is connected between TDI and TDO when the TAP controller is moved to the Shift-DR
state.
These instructions are Reserved for Future Use. In this device they replicate the BYPASS instruction.
28/38
GS88118B(T/D)/GS88132B(T/D)/GS88136B(T/D)